
31
Radiance
®
Direct Vent Gas Heater
20306759
LG490
all logs
6/07
Operation
The Radiance is operated with the front plate in place with
the doors open or closed. To open the front doors, pull
forward to separate the magnetic catch.
Your First Fire
Read these instructions carefully and familiarize yourself
with the burner controls shown on Page 32. Locate the
pilot assembly, Figure 56. Follow the lighting instructions
on Page 32 exactly.
During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being heated.
Odors should dissipate within the first eight to ten hours,
however, you can open a window to provide fresh air to
alleviate the condition.
ST477a
Stardance
pilot location
10/4/00
Fig. 56
Pilot Assembly location.
ST476
Pilot Assembly
Flame & Temperature Adjustment
For stoves equipped with HI/LO valves, flame adjustment
is accomplished by rotating the HI/LO adjustment knob
located near the center of the gas control valve. (Fig. 58)
Fig. 58
Flame adjustment knob for SIT valve.
LO
HI
FP390
FLAME ADJUSTMENT KNOB
11/21/96
Turn
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
Fig. 58
Correct pilot and burner flame appearance.
Flame Characteristics
It is important to periodically perform a visual check of the
pilot and the burner flames. Compare them to Figure 58. If
any of the flames appear abnormal, call a service person.
CO105d
Pilot flame
6/07 djt
Pilot and Burner Inspection
Each time you light your heater check that the pilot flame
and burner flame patterns are as shown in Figure 57. If
flame patterns are incorrect, turn the heater off. Contact
your dealer or a qualified gas technician for assistance.
Do not operate the heater until the pilot flame is correct.
Follow regular maintenance procedures as described on
Page 41.