35
Radiance
®
Direct Vent Gas Heater
30004967
. Use the ON /
▲
button to
set the desired On Delay
Time from 0 to 15 min-
utes.
3. Use the OFF /
▼
button to
set the desired Off Delay
Time from 0 to 15 min-
utes.
4. If there is no input within
3 seconds, the new set-
ting will be transmitted to
receiver.
5. The default settings for both transmitter and receiver
are 5 minutes for ON delay time and 8 minutes for OFF
delay time.
Low Battery Detection
Figure 67
1. Battery voltage is checked
once a minute. When the
battery voltage drops to a
certain level, the low-bat-
tery icon will display on
LCD, and the transmitter
will turn off the appliance.
The transmitter will not
function anymore until fresh
batteries are installed.
. When the batteries are low,
the LCD displays a low bat-
tery indicator. The low battery indicator will be displayed
in any mode.
3. The transmitter will not operate with low batteries.
Change the batteries before the batteries are too weak
for normal operation. Turn the unit OFF before replacing
batteries.
Child-Proof Protection
Figure 68
1. Press and hold the ON and
OFF buttons simultane-
ously for three (3) seconds
to enter child proof mode.
. The transmitter will not
send a signal again until
the childproof mode is
deactivated by pressing
the ON and OFF buttons
simultaneously for three
(3) seconds to exit child
proof mode. The Child-
proof indicator disappears from LCD.
FP146
FP2146
blower delay timer
12/08
Fig. 66
Blower time delay
display.
FP150
°F
FP2150
low battery display
12/08
Fig. 67
Low battery
display.
°F
FP2151
no child display
12/08
FP151
Fig. 68
Child protection
display.
Transmitter Thermal Shutdown
Figure 69
1. If transmitter measures a
room temperature exceed-
ing 99° F, the LCD will
display "HI" and the trans-
mitter will turn off the appli-
ance.
. Transmitter will not function
until the room temperature
has dropped below 99° F.
If transmitter measures
a room temperature less
than 40° F, the LCD will
display "LO" and NO SIGNAL will be sent to turn on the
appliance.
Receiver
Slide Switch
1. ON position: The main burner will ignite and blower will
come on when blower on delay time is reached and
fan speed has been enabled, the flame height is max;
otherwise just burner will ignite until the slide switch is
placed in the OFF or RS position to turn burner off.
. RS position: The system will only operate if the remote
receiver receives a signal from the transmitter.
3. OFF position: The system is off. If fan speed has been
enabled, blower will continue to operate until OFF delay
time expires. The slide switch should be placed in the
OFF position if you will be away for an extended period
of time. If the remote receiver is mounted out of reach
of children, the OFF position also functions as a safety
device by both turning the system off and rendering the
receiver inoperable.
Optional 6 Hour Shutdown
1. The receiver comes preset from the factory with a 6
hour shutdown from its last ON or flame lower operation.
This is done to prevent the appliance from continuing
to operate if unattended.
. You may disable this feature if you wish. To disable,
change the receiver privacy (DIP) switch #1 ONLY to
the OFF position. Make sure the transmitter privacy
(DIP) switches are set the same as the receiver. Follow
the instructions on how to set the privacy (DIP) switch
setting.
3. By disabling this feature, your appliance may continue
operating unattended.
FP2152
thermal shutdown display
12/08
FP15
Fig. 69
Thermal shutdown
display.