53
53
3-90-20306759
Vermont Castings • Radiance RADVT Installation Manual_R20 • 09/18
Figure 9.3
6LJQDWXUH&RPPDQG:LULQJ'LDJUDP
A/C MODULE
TO JUNCTION BOX
IN FIREPLACE
PLUG-IN
CONNECT
OR
WHITE
BLACK
BLACK
WHITE
GREEN
Opt. Blower
Opt. Aux.
Control Board
RF Receiver
ON/OFF Button
Pilot
Black / Thermopile
Red / Thermopile
Sensor
Ignitor / Sparker
Conversion
NG/LP
Plug-in Connector
Control Board to Command Center
OFF/LO
LED
ON/HI
Master Switch
Command Center
Optional
Wall Switch
Plug-in Connector
Stepper Motor to
Control Board
NOTE: Wall switch wires
must be connected together
if a wall switch is not being used.
DC Power/Green
Ground
Plug-in Connector
Control Board to
Solenoid
Gas In
Gas Out
Pilot Gas Tubing
Valve
300 Watt
Max.
Figure 9.4
%ORZHU:LULQJ'LDJUDP
To Junction Box
In Fireplace
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
Connector
Pin To Contro l Box
{
{
Light
Optional
AUX