KHLDV Series Gas Fireplace
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS
Function
Operation
Default Setting
Intermittent/Standing
Pilot Setup
Hold the ON
button while turning on the master switch (Beep once for
standing pilot, twice for intermittent pilot)
Intermittent Pilot
Standing Pilot Temp.
Shutoff
Hold the ON
button 3 seconds (when the master switch on the main
burner is off)
RF Remote Receiver
On/Off
Push the RF receiver On/Off button on the control board. (Beep once for
ON and beep twice for OFF.)
RF OFF
Learn Remote Trans-
mitter
Hold the OFF
button while turning on the master switch (Beep twice
then press any handheld remote button)
6-hour safety shut-
down setup
Press the ON
button and OFF
button simultaneously (Beep once
for ON, twice for OFF)
ON
Either mode bene
fi
ts from the instantaneous battery back-
up, so you never have to worry about a power outage.
NOTE:
The Signature Command System comes standard
in the Intermittent Pilot mode, so you must follow the in-
structions below to switch to Standing Pilot Mode if needed.
Intermittent/Standing Pilot Setup (Default intermittent)
1. Holding the ON button on the Command Center while
turning on the master switch will toggle between stand-
ing pilot and intermittent pilot.
2. After the above operation, one beep (for standing pi-
lot) or two beeps (for intermittent pilot) will be given as
con
fi
rmation.
Six-hour Safety Shutdown Option (Default ON)
1. The system comes preset from the factory with a six
(6) hour shutdown from its last command of operation.
This is done to prevent the
fi
replace from continuing to
operate if unattended. You may disable this feature if
you wish.
NOTE:
By disabling this feature, your
fi
replace may con-
tinue to operate unattended.
2. When the master switch is in the ON position (“-”),
pressing the ON button and the OFF button on the
Command Center simultaneously will toggle between
enabling and disabling the six-hour shutdown option.
3. After the above operation, one beep (for enabling the
six-hour shutdown option) or two beeps (for disabling the
six-hour shutdown option) will be given as con
fi
rmation.
Remote Transmitter Learn Function (Default OFF)
1. The RF receiver button located on the Control Board
must be in the on position before the learn function can
begin. Use paper clip to depress button. One beep for
RF receiver ON or two beeps for RF receiver OFF will
be given as con
fi
rmation. Refer to
Figure 42
for location.
2. After the RF receiver is on, holding the OFF button on
the Command Center while turning on the master switch
will activate the learn function for the transmitter.
3. After the above operation, two beeps will be given and
the green LED on the Command Center will
fl
ash for
10 seconds.
4. During the 10 seconds, press the OFF button on a
transmitter to learn. Another two beeps will be given
to con
fi
rm a successful learning. Refer to transmitter
instructions for remote operations.
Shutting Off the Standing Pilot (Temporary Shut Off)
To shut off the standing pilot for service or summer shut
down, press and hold the ON button on the Command
Center for 3 seconds when the master switch is in the ON
position (“-”) and the main burner is off.
Note
: Pilot will resume the next time system is turned on.
KEY COMBINATIONS FOR SYSTEM
SETTINGS
NOTE:
When On/Off wall switch is used, it must be in the
On position to perform all system setups.