background image

3

Vermont Castings GPF

General Information

Model GPF is a decorative gas log set for outdoor use
only. This appliance must not be used for cooking.

IMPORTANT: 

Read all instructions and warnings

carefully before starting installation. Failure to follow
these instructions may result in a possible fire hazard
and will void the warranty.

WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause injury or
property damage. Read the installation, operating and
maintenance instructions thoroughly before installing or
servicing this equipment.

WARNING: This appliance shall be used only outdoors
in a well-ventilated space and shall NOT be used inside
a building, garage or any other enclosed area.

WARNING: This log set must NOT be installed in an
unvented appliance.

WARNING: This unit is not for use with solid fuel.

NOTE: All new LP cylinders (and in many cases used
cylinders) may contain water, air or other contaminants,
and it is essential that these be removed before filling
the cylinder and placing into service. Water vapor
present in the gas vapor may cause the regulator to
“freeze up” and cause an interruption to the gas flow.
This interruption will cause the unit to shut down. To
prevent this form occurring it is essential that a
qualified individual ALWAYS purge a new tank
thoroughly before placing it into service. It is
recommended that cylinders that have not been used
for extended periods of time also be purged before use.

The installation must conform with Local Codes or, in
the absence of local codes, with the National Fuel Gas
Code ANSI Z223.1 or CSA-B149.1 Installation Code.

The appliance and its individual shut off valve must be
disconnected from the gas supply piping system during
any pressure testing or the system at test pressures in
excess of 1/2 psig (3.5kPa).

This appliance must be isolated from the gas supply
piping system by closing its individual manual shut off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/
2 psig (3.5kPa).

The following clearances to combustible construction
must be maintained: Bottom - 0 inches (0mm), Sides
(all around) - 16 inches (406mm) and Top - (7 feet
(2.1m).

Always keep the appliance area clear and free from
combustible materials, gasoline and other flammable
vapors and liquids.

Do not locate appliance where it can get excessively
wet. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the unit and to replace any part of
the control system and any gas control which has been
under water.

Children and adults should be alerted to the hazards
of high surface temperatures and should stay away to
avoid burns or clothing ignition.

Young children should be carefully supervised when
they are in the area of the appliance.

Never leave unit unattended during operation.

Clothing or other flammable materials should not be
hung from the appliance, or placed on or near the
appliance.

Any guard or other protective device removed for
servicing the appliance must be replaced prior to
operating the appliance.

Installation and repair should be done by a qualified
service person. The appliance should be inspected
before use and at least annually by a qualified service
person. More frequent cleaning may be required as
necessary. It is imperative the control compartment,
burners and circulating air passageways of the
appliance be kept clean.

Inspect the fuel supply connection (including the hose
for LP models) before each use of the appliance.

If it is evident there is excessive abrasion or wear, or
the hose is cut, it must be replaced prior to the
appliance being put into operation.

The pressure regulator and hose assembly supplied
with LP models must be used. Replacement pressure
regulators and hose assemblies must be those
specified in this manual.

The LP gas supply cylinder used with LP models must
be constructed and marked in accordance with the
specifications for LP gas cylinders of the U.S.
Department of Transportation (DOT).

Cylinders must be stored outdoors in a well-ventilated
area out of reach of children. Disconnected cylinders
must have threaded valve plugs tightly installed and
must not be stored in a building, garage or any other
enclose area.

Storage of this appliance indoors is permissible only
it has been disconnected from its fuel supply (natural
gas line or LP gas cylinder).

The LP gas cylinder supply system must be arranged
for vapor withdrawal.

The LP gas cylinder used must include a collar to
protect the cylinder valve.

When an LP model is not in use, the LP gas must be
turned off at the supply cylinder.

Summary of Contents for GPFMN

Page 1: ...s or any other appliance FOR YOUR SAFETY If you smell gas Do not touch any electrical switches Do not try to light any appliance Extinguish any open flame Do not use the phone in your build ing Immedi...

Page 2: ...allation 4 Log Placement 7 Operation 9 Maintenance 10 Replacement Parts 11 Accessories 12 11 292mm 5 127mm 12 305mm 3 83mm 16 413mm 11 289mm 8 210mm Burner GPF Dimensions 4237 Fig 1 Physical dimension...

Page 3: ...area clear and free from combustible materials gasoline and other flammable vapors and liquids Do not locate appliance where it can get excessively wet Do not use this appliance if any part has been u...

Page 4: ...proper external mating threads Tank valve Marked USE WITH TYPE 1 5 Inspect hose shipped with the unit for damage Never attempt to use damaged or plugged equipment See your local LP Gas Dealer for rep...

Page 5: ...and operation A door on the enclosure to gain access to the cylinder valves is acceptable provided it is nonlocking and can be opened without the use of tools 4 There shall be a minimum clearance of 2...

Page 6: ...7 16 3 4 and 11 16 wrenches phillips screwdriver Installation Instructions 1 Remove octagonal plate from shipping carton 2 Remove base Villa from shipping carton Remove four 4 1 4 20 fasteners four 4...

Page 7: ...ly through the fuel line opening in the base Place the octagonal mounting plate on the Chalet Fig 8 Orient the plate with the long side of the rectangular opening parallel to the valve panel Pass the...

Page 8: ...over on or removing the cover from the unit to avoid damaging the logs CAUTION Log C4 Log C5 Log C1 Log C2 LG165a Fig 14 Log C5 placement Log C5 Log C1 Log C6 Log C4 Log C2 Log C3 LG166a Fig 15 Log C6...

Page 9: ...re to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not us...

Page 10: ...the hose connecting the LP gas cylinder to ensure it is not damaged in any way High Elevation Installation This U L listed gas appliance is tested and approved for elevations form 0 to 2 000 feet in...

Page 11: ...tural Supply Line 50000198 7a Short Stem Orifice Natural 20004497 7b Short Stem Orifice LP 20004498 8 Volcanic Rock 20000198 9 LP Gas Cylinder Base 20004578 10 LP Conversion Kit 20004752 11 NG Convers...

Page 12: ...el Number Patio Fire Optional Safety Screen Kit PFOSK Villa Patio Fire Urn Base PFCBUMB Chalet Patio Fire Octagonal Base PFCBOMB CAUTION This appliance is a highly engineered system and as such must b...

Page 13: ...mont Castings Majestic Products Company sont garanties pour la vie de l acheteur d origine le tout sujet une preuve d achat et aux conditions et limitations suivantes 1 Ce nouveau produit Vermont Cast...

Page 14: ...ngs GPF 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com The Vermont Castings Majestic Products Company The Vermont Castings Majestic P...