background image

4. Remove the rear shroud held by two Phillips round head machine screw in the center and four sheet metal 
screws - two on each side.  This allows access to the six hex head nuts and washers holding the damper housing 
assembly and the fireback retainers.

FIG. 6  Left damper housing showing one bolt removed

FIG. 7  Right fireback bracket removal

7. Slide the fireback brick forward and out of the unit. 

8. Slide the fountain assembly out.

9. 

This completes the disassembly.

5. Remove the damper housing assembly.  First remove the damper handle with the Allen key supplied with the 
unit (FIG. 5).  Locate and remove the four hex head through bolts, two per side on the outside of the inner back, 
that hold the upper fireback in place (FIG. 6).  The nuts and washers are on the outside of the back.  This may 
require the use of two 7/16" wrenches.  Gently rotate the damper housing down right side first and maneuver out 
of the firebox by sliding left to right to clear the damper rod from the left side.  Please locate damper rod spacer 
and remove from the hole in the side for reinstalling.  Ensure damper rod washer is in place near the end (FIG. 
8).  This prevents the rod from sliding out of position when re-installed.

6. Remove the fireback.  Locate the two hex 
nuts on the outside of the inner back that hold 
the lower refractory brackets in place (FIG. 7).  
The nuts and washers are on the outside of 
the back.  This may require the use of two 
7/16" wrenches.  Remove the two hex nuts 
with washers and pull out the hex head cap 
screws holding the brackets.  This may require 
the use of two 7/16" wrenches.  Remove the 
brackets.  Hold the top of the fireback while 
removing the brackets as it will fall forward with 
the brackets removed.

FIG.5  Remove damper handle