Vermont Castings Brookhaven 20DVT Installation Instructions And Homeowner'S Manual Download Page 31

10009459

31

Brookhaven Direct Vent Gas Fireplace

BASIC WARRANTY

 

CFM Corporation (hereinafter referred to collectively as the Company) 
warrants that your new Vermont Castings

 

or Majestic Gas Fireplace/

Stove is free from manufacturing and material defects for a period of 
one year from the date of purchase, subject to the following conditions 
and limitations.

EXTENDED LIFETIME WARRANTY

 

The  heat  exchanger,  where  applicable,  and  combustion  chamber 
of every Vermont Castings

 or 

Majestic gas product is warranted for 

life against through wall perforation. All appliances equipped with an 
Insta-Flame  Ceramic  Burner  have  limited  lifetime  coverage  on  the 
ceramic burner plaque. Warrantees are made to the original owner 
subject to proof of purchase and the conditions and limitations listed 
on this Warranty Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a 
period of three years.

 

Note

: On porcelain enamel finished external parts and accessories The 

Company offers no Warranty on chipping of enamel surfaces. Inspect 
all product prior to accepting it for any damage to the enamel.

 

 The salt air environment of coastal areas or a high humidity environment 
can be corrosive to the porcelain enamel finish. These conditions can 
cause rusting of the cast iron beneath the porcelain enamel finish, 
which will cause the finish to flake off.

 

Dye lot variations with replacement parts and/or accessories can occur 
and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year. 
Glass doors are not warranted for breakage due to misuse or accident.  
Glass doors are not covered for discoloration or burned in stains due to 
environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be 
cleaned with Lemon oil only.

 

Brass cleaners cannot be used.  Mortar 

mix and masonry cleaners may corrode the brass finish.  The Company 
will not be responsible for, nor will it warrant any brass parts which are 
damaged by external chemicals or down draft conditions.
GAS VALVES: Gas valves are covered for a period of one year
ELECTRONIC  AND  MECHANICAL  COMPONENTS:  Electronic  and 
mechanical components of the burner assembly are covered for one year. 
All steel tube burners are warranted for one year.
ACCESSORIES:  Unless  otherwise  noted  all  components  and  CFM 
Corporation company supplied accessories are covered for a period of 
one year.

CONDITIONS AND LIMITATIONS

•  This new Vermont Castings or Majestic product must be installed by 

a competent, authorized, service contractor. A licensed technician, as 
prescribed by the local jurisdiction must perform any installation/service 
work. It must be installed and operated at all times in accordance with 
the Installation and Operating instructions furnished with the product. 
Any alteration, willful abuse, accident, or misuse of the product shall 
nullify this warranty.

•  This warranty is non-transferable, and is made to the original owner, 

provided that the purchase was made through an authorized supplier 
of the Company.

•  The customer must pay for any Authorized Dealer in-home travel fees 

or service charges for in-home repair work. It is the dealers option 
whether the repair work will be done in the customer’s home or in the 
dealer’s shop.

•  If upon inspection, the damage is found to be the fault of the manufacturer, 

repairs will be authorized at no charge to the customer parts and/or 
labor.  

•  Any  part  and/or  component  replaced  under  the  provisions  of  this 

warranty is covered for six months or the remainder of the original 
warranty, whichever is longest.

•  This warranty is limited to the repair of or replacement of part(s) found 

to be defective in material or workmanship, provided that such part(s) 
have been subjected to normal conditions of use and service, after 
said defect is confirmed by the Company’s inspection.

•  The  company  may,  at  its  discretion,  fully  discharge  all  obligations 

with respect to this warranty by refunding the wholesale price of the 
defective part(s)

•  Any installation, labor, construction, transportation, or other related 

costs/expenses  arising  from  defective  part(s),  repair,  replacement, 
or otherwise of same, will not be covered by this warranty, nor shall 
the Company assume responsibility for same. Further, the Company 
will not be responsible for any incidental, indirect, or consequential 
damages except as provided by law.

•  SOME  STATES  DO  NOT  ALLOW  FOR  THE  EXCLUSION  OR 

LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES 
OR  LIMITATIONS  ON  HOW  LONG  AN  IMPLIED  WARRANTY 
LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR 
CIRCUMSTANCES.    THIS  WARRANTY  GIVES  YOU  SPECIFIC 
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM 
STATE TO STATE. 

•  All other warranties-expressed or implied- with respect to the product, 

its components and accessories, or any obligations/liabilities on the 
part of the Company are hereby expressly excluded.

•  The  Company  neither  assumes,  nor  authorizes  any  third  party  to 

assume on its behalf, any other liabilities with respect to the sale of 
this Vermont Castings or Majestic product

•  The  warranties  as  outlined  within  this  document  do  not  apply  to 

chimney components or other non CFM Corporation accessories used 
in conjunction with the installation of this product..

•  Damage to the unit while in transit is not covered by this warranty but 

is  subject  to  claim  against  the  common  carrier.  Contact  the  dealer 
from whom you purchased your fireplace/stove (do not operate the 
appliance as this might negate the ability to process the claim with the 
carrier).

•  The Company will not be responsible for:

a)  Down drafts or spillage caused by environmental conditions such 

as near-by trees, buildings, roof tops, hills, or mountains.

b)  Inadequate  ventilation  or  negative  air  pressure  caused  by 

mechanical systems such as furnaces, fans, clothes dryers, etc.

•  This warranty is void if:

a)  The fireplace has been operated in atmospheres contaminated by 

chlorine, fluorine, or other damaging chemicals.

b)  The fireplace has been subjected to prolonged periods of dampness 

or condensation

c)  Any damages to the fireplace, combustion chamber, heat exchanger 

or other components due to water, or weather damage, which is the 
result of but not limited to, improper chimney/venting installation.

d)  Any alteration, willful abuse, accident, or misuse of the product 

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1)  Contact  your  supplier.    Make  sure  you  have  your  warranty, 

your sales receipt, and the model/serial number of your  CFM 
Corporation product.

2)  DO  NOT  ATTEMPT  TO  DO  ANY  SERVICE  WORK 

YOURSELF.

LIMITED LIFETIME WARRANTY 

PRODUCT COVERED BY THIS WARRANTY

All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with 
an Insta-Flame Ceramic Burner, or standard steel tube burner.

Summary of Contents for Brookhaven 20DVT

Page 1: ...the re department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLO SION MAY RESULT CAUSING PROPERTY DAMAGE PER SONAL INJURY OR LOSS OF LIFE PLEASE READ THIS MANUAL BEF...

Page 2: ...Gas Line Installation 6 General Venting Information General Venting 7 General Venting Information Termination Location 8 General Information Assembling Vent Pipes 9 Flex Vent Pipes 9 Twist Lock Pipes...

Page 3: ...on and ventilation air must not be ob structed in any way 11 When replace is installed directly on carpeting vinyl tile or any combustible material other than wood the replace must be installed on a m...

Page 4: ...ions L 31 806 mm M 44 1140 mm N 23 587 mm O 21 540 mm P 34 864 mm Q 15 394 mm 20DVT Fireplace Dimensions Fig 2 Fireplace speci cations and framing dimensions O Rough Opening Width K F Q Rough Opening...

Page 5: ...From Side Ref Leg Depth Ref of Comb Opening F 12 305 mm K 12 305 mm G 9 229 mm L 9 229 mm H 6 152 mm M 6 152 mm I 4 102 mm N 4 102 mm J 3 76 mm O 3 76 mm Fig 3b Combustible mantel leg minimum installa...

Page 6: ...r elevations above 4 500 feet 1 370m in USA installations must be in accordance with the cur rent ANSI Z223 1 NFPA 54 and or local codes hav ing jurisdiction In Canada please consult provincial and or...

Page 7: ...tall switch into receptacle box Attach cover plate to switch 3 Connect wiring to gas valve Fig 6 TPTH TH TP FP1218 Remote switch wiring 8 02 Remote ON OFF Switch FP1218 Fig 6 Remote switch wiring diag...

Page 8: ...91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet to any Btuh 3kW 12 30cm for 10 000 Btuh 3kW 9 othe...

Page 9: ...e Apply High Tem perature Sealant Hose Clamp FP1471a Fig 8 Apply high temperature sealant to 4 and 7 pipes Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with...

Page 10: ...k Pipes When using CFM Corporation twist lock pipe it is not necessary to use sealant on the joints The only areas of the venting system that need to be sealed with high temperature silicone sealant a...

Page 11: ...duced to 17 5 2 m In Figure 13 Dimension A plus B must not be greater than 17 5 2 m The maximum number of 45 elbows permitted per side wall installation is two 2 These elbows can be installed in eithe...

Page 12: ...p i e from the elbow to the outside wall nish plus 2 or the distance required if installing a second 90 elbow Fig 18 Always install horizontal venting on a level plane X X FP1181 Fig 17 Vertical heigh...

Page 13: ...pacer springs 6 165mm FP1475 flex 90 bend 4 04 djt FP1475 Fig 20 Bend ex vent at 90 so horizontal portion is 6 165 mm off top of unit STEP 4 Install the 4 102 mm ex vent pipe to the appliance collar a...

Page 14: ...the horizon tal plane the maximum horizontal length must be reduced by 18 450 mm Example Maximum horizontal length No elbows 10 3 m 1 x 45 elbow 8 5 2 6 m 2 x 45 elbows 7 2 1 m A minimum of an 8 2 5m...

Page 15: ...In all cases the opening must provide a mini mum of 1 25 mm clearance to the vent pipe i e the hole must be at least 9 x 9 240 x 240 mm 5 Place replace into position 6 Place restop s 7DVFS or Attic In...

Page 16: ...r Vent to Vertical Vent 90 Elbow 7TDV90 Vertical Horizontal Offset Telescopic vent sections 7TDVP1117 11 to 17 adjustable length 7TDVP3567 35 to 67 adjustable length Pipe sections for vertical or hori...

Page 17: ...onia household cleaner and warm water gas replace glass cleaner is recommended After the initial cleaning process the glass should be cleaned two or three times during each operating season depending...

Page 18: ...n of Logs The logs are fragile and should be handled with care Keep the packaging material out of the reach of children and dispose of the mterial in a safe manner The individual logs can be easily id...

Page 19: ...tating the Hi Lo adjustment knob located near the centre of the gas control Fig 33 or 34 Flame Characteristics It is important to periodically perform a visual check of the pilot and the burner ames C...

Page 20: ...tly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try t...

Page 21: ...rning no gas to A Wall switch or wires defective Check wall switch and wires for proper connections main burner Jumper wires across terminals at wall switch if burner comes on repalce defective wall s...

Page 22: ...m assembly FC107 D E F FC108 SIT regulator conversion 10 03 OF F P I L O T O FC108 Fig 38 Replace regulator Burner Ori ce Conversion 1 Remove two 2 burner housing assembly mounting screws Fig 39 2 Lif...

Page 23: ...stall conversion pilot ori ce 4 Reinstall pilot hood and be sure to align with index tab 5 Turn the gas supply valve and gas valve on and test for leaks Use a 50 50 solution of liquid soap and water t...

Page 24: ...May Be HOT 1 Turn off pilot light at gas valve side 2 Let replace cool if it has been running 3 Remove window frame assembly Refer to Window Frame Assembly Removal section 4 Remove logs 5 Vacuum burn...

Page 25: ...a 1b 2 3 4 5 7a b 8a b 12 13 9 14 10 16 17 18 20 21 22 24 9459 20DVT parts 5 06 19 15 Ref Description 20DVT 1 Log Set Complete 10009451 1a Log Rear J11 1b Log Front J12 2 Lava Rock Pkg 10001454 3 Embe...

Page 26: ...ctrode Ignitor w Cable RN RP 10001297 15 Ignitor Piezo w Nut 50932 16 Valve SIT 820 662 RN 20010563 17 Flexible Gas Line w ON OFF Shut Off Valve 10009064 18 Frame Window w Glass Assy 10009485 19 Conso...

Page 27: ...nd supported Installation Instructions 1 Remove window frame assembly and logs 2 Place rear ceramic panel in back of unit Fig 44 3 Place side panels 4 Re install logs and window frame assembly Optiona...

Page 28: ...Brookhaven Direct Vent Gas Fireplace 28 10009459...

Page 29: ...10009459 29 Brookhaven Direct Vent Gas Fireplace...

Page 30: ...Brookhaven Direct Vent Gas Fireplace 30 10009459...

Page 31: ...p Ifuponinspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of t...

Page 32: ...Ratings EnerGuide Ratings D O E Model Fireplace Ef ciency Steady State AFUE 20DVTRN 60 1 80 64 20DVTRP 60 1 81 64 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM C...

Reviews: