CFDV Series Gas Fireplace
14
20305832
VENTING INSTALLATION
Outside Corner
Inside Corner
G =
Combustible
6" (152 mm)
Noncombustible
2" (51 mm)
F =
Combustible
6" (152 mm)
Noncombustible
2" (51 mm)
G
Balcony -
with no side wall
M =
Combustible &
Noncombustible
12" (305 mm)
M
Balcony -
with perpendicular side wall
M =
12" (305 mm)
P =
6” (152 mm)
M
F
Alcove Applications*
C
D
C
E
V
V
Combustible &
Noncombustible
E
= Min. 2” (51 mm) for
non-vinyl sidewalls
Min. 12” (305 mm) for
vinyl sidewalls
O
= 8’ (2.4 m) Min.
O
P
V
V
V
584-15
D
Min.
= Number of Termination caps x 3
C
Max.
= (2 / Number termination caps) x D
Actual
*NOTE:
Termination in an alcove space (spaces open only on one side
and with an overhang) is permitted with the dimensions specifi ed for
vinyl or non-vinyl siding and soffi ts. 1. There must be a 3' (914 mm) min-
imum between termination caps. 2. All mechanical air intakes within 10'
ASSEMBLING VENT PIPE
Only venting components manufactured or approved by
Vermont Castings Group may be used in Direct Vent sys-
tems.
USA Installations
The venting system must conform to local codes and/or
the current National Fuel Code ANSI Z223.1/NFPA 54.
Canadian Installations
The venting system must be installed in accordance with
the current CSA-B149.1 installation code.
FLEX VENT PIPE
Secure fl ex vent pipe in place with a hose clamp (provid-
ed).
•
Be sure the fl ex pipe overlaps at least 1" (25 mm) onto
the collars of the fi replace and termination. If the ter-
mination has an internal bead, be sure to overlap and
secure 1" (25 mm) past the bead.
•
Tighten fl ex clamp to fl ex pipe so it is tight to collar and
cannot slip off.
•
Apply a tug to be sure the vent will not slip off the col-
lars.
•
Repeat process with 7" fl ex vent pipe. The same pro-
cedure must be performed on the vent side.
Hose Clamp
FP2290
Figure 17 –
Secure Flex Vent Pipe with Hose Clamps.
Figure 16 –
Termination Clearances
(1 m) of a termination cap must be a minimum of 3' (914 mm) below the
termination cap. 3. All gravity air intakes within 3' (914 mm) of a termina-
tion cap must be a minimum of 1' (305 mm) below the termination cap.
TERMINATION CLEARANCES
Termination clearances for buildings with combustible and non-combustible exteriors.
No. of
Caps
D
MIN
.
C
MAX
.
1
3' (914 mm) 2 x D
ACTUAL
2
6' (1.8 m)
1 x D
ACTUAL
3
9' (2.7 m)
2/3 x D
ACTUAL
4
12' (3.7 m) 1/2 x D
ACTUAL