19.  Using a 7/16” nut driver, remove the threaded plug 

from the test port.

20.  Thread the supplied extension adaptor into the 

open test port.

21.  Attach a 1/4” diameter pressure gauge flexible hose 

fully onto the barb of the adaptor.

22.  Turn on gas supply and operate valve with remote 

control as needed to indicate gas pressure. The 
manifold pressure for LP should be approximately 
10.0” wcp.

CAUTION:

 Turn off the valve and gas supply 

before removing test port adaptor and replac-
ing plug.

23.  After test, remove adaptor and replace plug.
24.  Turn on gas supply and check that plugs are tight 

and leak free.

25.  Follow instructions in Homeowner’s Manual to 

re-assemble brick panels, logs, lava rock, volcanic 
rock, embers and andirons.

26.  Replace glass frame.
27.  Conversion complete.

Pilot Flame Adjustment

Typically, the top 3/8” or 1/2” of the thermopile should 
be engulfed in the pilot flame. (Fig. 8)
To adjust pilot burner:  Adjust pilot screw on valve to 
provide properly sized flame..

13.  Reinstall burner to original position. Reinstall burner 

leg, burner tube and fettle. Re-attach supply tube to 
gas supply fitting. Using a back-up wrench, tighten 
securely.

14.  Test for leaks. Apply electric and gas to the system.
15.  Light the pilot burner using the remote control. With 

soapy solution check for leaks around the pilot as-
sembly where the tube enters the pilot assembly. 
Tighten fitting if necessary.

16.  Light the main burner and check for leaks around 

the burner supply tube fittings and burner orifices. 
Tighten if necessary.

17.  Turn fireplace OFF.
18.  After the conversion and leak checks have been 

made, manifold outlet pressure can be checked 
with a manometer at the test ports located at the 
side front edge of the fireplace opening. The lower 
test port is manifold outlet pressure.

CAUTION:

 Turn off the gas supply before 

removing test port plug.

�����
�����������������������
����

��

��

��

��

Minimum Rate 
Screw

CO137

Fig. 7

  Remove black plastic cap and adjust rotary knob to 

correct gas type.  (LP position shown) Replace minimum rate 
screw with one supplied in conversion kit.

Gas Type 
Marker

Pilot Adjustment Screw

FP1229a

Pilot flames

4/03

FP1229a

Fig. 8

   Correct pilot flame appearance.