Vermont Castings 20011992 Installation Instructions Download Page 2

2

2

CO134

AF pilot orifice

3/07

Index Tab

Snap Ring

Allen Wrench

CO134

Fig. 5

  Remove pilot orifice.

CO133

pilot hood

3/07

Pilot 

Bracket

Pilot Hood

CO133

Fig. 4

  Remove pilot hood.

FP1476

bracket screws

4/04  djt

Hex Nuts

FP1476

Fig. 3 

 Use a 3/8” socket to remove hex nuts holding burner 

legs.

burner assembly on both sides. Remove burner 
tubes.

b.  Remove two (2) hex nuts holding the left burner 

leg. Remove burner leg. (Fig. 3)

c.  Remove two (2) screws holding the pilot assem-

bly to the burner assembly. Move the pilot assem-
bly toward the back. 

d.  Slide the burner housing assembly to the left and 

away.

e.  Replace the four (4) injectors. Refer to Table 3.

5.  Remove pilot orifice with 5/32” Allen wrench. (Fig. 5)
6.  Install the conversion orifice.
7.  Reinstall pilot hood. Be sure to align hood with index 

tab.

Valve Conversion

1.  Remove two (2) screws holding the pilot assembly 

to the burner assembly. Move the pilot assembly 
toward the back wall.

2.  Using a back-up wrench, disconnect the gas supply 

fitting near the right rear corner of the firebox.

3.  Remove four (4) screws holding the burner assem-

bly to the firebox floor.

4.  Carefully slide the burner assembly out of the way.
5.  Remove 13 screws around the perimeter holding 

large access panel on the of the firebox.

6.  Carefully pull back the panel just enough to gain 

access to control box.

7.  Locate the black plastic cap on the gas valve. (Fig. 

6) Remove the black cap by pulling the cap straight 
off. Note the position of the marker on the top of 
the rotary knob. This marker will point to NAT or LP. 
(Fig. 7)

�����
��������
����

Black Plastic Cap

Minimum Rate 
Screw

CO138

Fig. 6

  AF4000 Valve in place.

Front of Fireplace

Replace Pilot Orifice

4.  Remove pilot hood by lifting up. (Fig. 4) 

NOTE:

 It is 

not necessary to remove the pilot tube for conver-
sion. 

8.  To convert the valve from NG to LP, push in the 

knob and rotate 90° (1/4 turn). 

NOTE:

 The shaft 

should point to LP. The shaft will remain pushed-in.

9.  Remove the slotted brass minimum rate screw 

located in the valve next to the motor drive. (Fig. 7)

10.  Replace the minimum rate screw with the one 

provided in the LP conversion kit supplied with this 
fireplace. Ensure the screw is fully installed.

11.  Install the enclosed identification label to the valve 

body where it can be easily seen.

12.  Reinstall steel panel.

Reviews: