Verizon User Manual
Smart-Cell Repeater
26
* Close the repeater door if opened and verify that
the closest indoor coverage antenna is not in the
same room as the repeater.
Field
Replaceable
module
failure
Filter service has not
matches between
Amp Unit and DFM
* Call to GST's Tech Support Team to verify that all
the settings are correct.
Tamper
Detected
When mount
information (in the
system ) is changed
* After 5 minutes clear automatically.
* If you want to disable, you can on the Alarm
Configuration page.
Communicat
ion Failure
If the communication
between the NMS
Board and Amp Unit
would not operating
normally
* SNMP board or AMP unit need to reset.
* Open the rear cover and check the each cable.
Power
Supply out
of range
The internal Power
Supply detects
improper Voltage
* If the system is working fine, disable the alarm on
the Alarm Configuration page.
* Call to GST's Tech Support Team to verify that all
the settings are correct.
Over
Temperature
Internal AMP
temperature exceeds
the Temperature
Limit
* Verify that the Temperature Limit is set between
176 °F ~ 201 °F on the RF Configuration page.
(Default Value is 163°F)
Reset alarm
When the unit has
reset
* After 30 seconds clear automatically.
Manual
Shutdown
When the operates
shutdown algorithm,
after re-check
* By using a switch on the back of the repeater,
resets the power
* Reset the AMP unit, By Web UI.
FAN
in the event of a fan
failure
* Replace the fan