SECTION 2:
INTRODUCTION TO THE V660 HDD EVO
The V660 HDD EVO degausser functions like a large electro magnet, its erasing field originating as leakage flux from a large
gap in the field structure, the V660 HDD EVO structure is basically a U section. The field intensity decreases rapidly as the
distance from the degausser surface increases. For example at a distance of approximately 2.75 inches from the
degausser's surface a field strength of only 50 oersteds exists. Furthermore, the erasing field present at the front edge
nearest the operator is also very low. It is therefore recommended that care should be taken to ensure the entire width of
tape to be erased is exposed to the effective field.
The vulnerability of information stored on PC hard drives is a recognised security risk. Unlike other PC data storage media
the hard drive always stays with the PC. Every time a PC leaves a company
’
s control all the data and company information
will go with it. Even if the hard drive breaks down the storage platters will still contain information which could be read once
repaired.
SECTION 3: INSTALLATION
Care should be taken when moving/handling the Degausser.
3.1 Unpacking
The degausser is shipped inside a cardboard packing case.
Unpack the degausser carefully by disassembling the packing
case and inspect it for signs of physical damage. If damage is apparent, a claim should be filed with the carrier immediately.
Once you have exposed the degausser, you can carefully remove it from the packing box. You should find the following:
V660 HDD EVO degausser
Power Cable
Infrared remote control switch
User Manual (This document)
3.2 Power Wiring
Check the power supply requirements on the label attached to the back of the equipment with the available supply. The unit
is supplied with a flying 3 wire cable which, when connected to a properly wired receptacle, earths the unit. It is essential that
a proper earth connection is made to assure safe operation.
CAUTION:
A good electrical ground must be connected to the degausser. The unit must be connected to the
correct power supply. Failure to do so may result in permanent damage.
Connections
IMPORTANT INSTRUCTION:
The mains supply outlet socket should be close to the installed equipment and fully
accessible.
NOTE:
The degaussing coils are powered as part of a tuned resonant circuit. This allows quite high circulating currents to be
generated within the degaussing coils, with minimal current consumption from the mains voltage supply. However, this
technique requires that the waveform of the supply voltage contains minimal harmonic distortion. A distorted waveform will
result in an increase in current consumption.
The typical current consumption figures provided in this manual are when powered from a supply with minimal distortion.
Any increase in current consumption due to a distorted waveform will have minimal effect on the degausser performance,
however, excessive current consumption should be avoided for obvious reasons. In the event of unexplained high currents,
please consult your supplier
.
Wire Colour
50Hz
Brown
Live
Blue
Neutral
Yellow/Green
Earth
Wire Colour
60Hz
Black
-
1
Hot
Black
-
2
Hot
Yellow/Green
Ground