background image

 

 

VS SECURITY PRODUCTS LIMITED

   

 

 

 

 

 

 

VS AND ASSOCIATES

 

Unit 17, Pegasus Court

 

 

 

 

 

 

 

 

 

3160, Texas Hill Road

 

North Lane

 

 

 

 

 

 

 

 

 

 

 

Placerville

 

Aldershot

 

 

 

 

 

 

 

 

 

 

 

California

 

GU12 4QP

 

 

 

 

 

 

 

 

 

 

 

95667

 

 

 

 

UK

 

 

 

 

 

 

 

 

 

 

 

USA

   

 

 

 

 

Summary of Contents for V660 HDD EVO

Page 1: ...ZZ009167 ZZ009171 Rev 11 ...

Page 2: ...st 2 metres 6 Feet from the degausser IMPORTANT the power on off switch used on this equipment is not an isolating switch it is recommended that this equipment should be operated from a separate switched isolator which should be located close to the unit and within reach of the operator COPYRIGHT This document is the property of VS Security Products Ltd and it may not be reproduced copied or exhib...

Page 3: ...SECTION PAGE 1 Specification 4 2 Introduction to the V660 HDD EVO 5 3 Installation 5 4 Operation 6 5 Indicators Features 8 6 Maintenance Service 9 7 Tables 10 8 Parts List 11 This document refers to V92 DIGI Tapemaster part no s ZZ009154 220 240v 50Hz ZZ009157 110 115v 60Hz ...

Page 4: ...ERATING VOLTAGE 220 240v 50Hz ZZ009167 208 220v 60Hz ZZ009171 CURRENT 10 amps typical 220 240v 50Hz 12 amps typical 208 220v 60Hz CIRCUIT BREAKER 10A 50Hz 16A 60Hz MOUNTING Free standing table top DIMENSIONS 19 x 16 5 x 7 48cm x 42cm x 18cm DIMENSIONS PACKED 25 5 x 20 8 x 10 6 65cm x 53cm x 27cm WEIGHT 57 lbs 26kg WEIGHT PACKED 62 lbs 28kg VS Security Products reserves the right to amend or modify...

Page 5: ...u can carefully remove it from the packing box You should find the following V660 HDD EVO degausser Power Cable Infrared remote control switch User Manual This document 3 2 Power Wiring Check the power supply requirements on the label attached to the back of the equipment with the available supply The unit is supplied with a flying 3 wire cable which when connected to a properly wired receptacle e...

Page 6: ...th the red power switch OFF lift the lid on the top of the degausser For completed erasure the hard drive should be subjected to the erase field in 4 positions 2 Place the hard drive into the foam receptacle with the drive s PCB facing UP and on the left hand side 3 Close the lid 4 Ensure the key switch is in the upright position indicating LOCAL operation See image A below 5 Press the red power s...

Page 7: ...7 After 3 5 seconds release the button and the remote control to stop erasure 8 Remove the hard drive and rotate it through 90 degrees and replace into the foam receptacle with the drive s PCB board facing UP nearest the operator 9 Close the lid 10 Repeat steps 5 7 above 11 Remove the hard drive flip it over and replace into the foam receptacle with the drive s PCB facing DOWN and on the left hand...

Page 8: ...The infrared transmitter LED illuminates when the remote control is in operation 5 4 Overheat Protection The high energy field developed by the V660 HDD EVO necessitates the generation of a considerable amount of heat The degausser coil is monitored for excessively high temperatures and should this condition occur its operation will be inhibited until the coil has cooled sufficiently 5 5 Cooling A...

Page 9: ...ailure the fan may easily be replaced from the rear of the degausser 6 4 Internal Components Most of the internal components are replaceable i e the solid state relay toroidal transformer and the thermal switches mounted on the degausser coil However the tuning capacitors and the degaussing coil are not spared items and if found to be faulty the unit should be returned to VS Security Products for ...

Page 10: ...pplier 7 2 Current Monitor Test Points The following table contains typical current values to be measured at specific points in the equipment The values given are in amperes and may differ slightly from those actually measured due to component tolerance plus effects due to operating temperature Function Symptoms Possible Fault Location Fails to degauss media Circuit breaker CB1 repeatedly tripped ...

Page 11: ...1 Relay SW3 SW100061 1 Temperature Sensor SW1 SW100123 1 Red lens SW1 SW100125 1 Switch Body SW1 SW100126 1 Switch Contact Block IND1 SW100121 1 Yellow lens IND1 SW100124 1 Indicator IND1 SW100127 1 Dummy Socket TX1 TX100027 1 Auto Toroid Transformer XX003065 1 Fan Plate SW2 SW100070 1 Mode Key Switch IND2 OI100064 1 LED Indicator SW2 SW100060 2 Thermal Switch CB1 SW100143 1 16A Circuit Breaker R1...

Page 12: ...SW3 SW100061 1 Temperature Sensor SW1 SW100123 1 Red lens SW1 SW100125 1 Switch Body SW1 SW100126 1 Switch Contact Block IND1 SW100121 1 Yellow lens IND1 SW100124 1 Indicator IND1 SW100127 1 Dummy Socket TX1 TX100027 1 Auto Toroid Transformer XX003065 1 Fan Plate SW2 SW100070 1 Mode Key Switch IND2 OI100064 1 LED Indicator SW2 SW100060 2 Thermal Switch CB1 SW100066 1 12A Circuit Breaker R1 RP20003...

Page 13: ...VS Security Products LTD ZZ009167 ZZ009171 Page 13 of 15 8 3 Circuit Diagram ZZ009167 50Hz ...

Page 14: ...VS Security Products LTD ZZ009167 ZZ009171 Page 14 of 15 8 4 Circuit Diagram ZZ009171 60Hz ...

Page 15: ...VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES Unit 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot California GU12 4QP 95667 UK USA ...

Reviews: