Verine Marcello NBFP00RN Installation, User And Servicing Instructions Download Page 15

 

15 

 

S

ERVICE AND 

M

AINTENANCE

 

 

BEFORE  ANY  SERVICING  IS  CARRIED  OUT  ISOLATE  THE  APPLIANCE 
FROM  THE  GAS  SUPPLY.    AFTER  REFITTING  THE  APPLIANCE,  CHECK 
FOR GAS SOUNDNESS AT ALL GAS JOINTS AND TEST FOR SPILLAGE. 

 

This  product  uses  fuel  effect  pieces  containing  Refractory  Ceramic  Fibre 
(RCF).  This  material  contains  man-made  vitreous  silicate  fibres.  Excessive 
exposure  to  these  materials  may  cause  temporary  irritation  to  eyes,  skin 
and  respiratory  tract;  consequently,  it  makes  sense  to  take  care  when 
handling  these  articles  to  ensure  that  the  release  of  dust  is  kept  to  a 
minimum. 

 

To  ensure  that  the  release  of  fibres  from  these  RCF  articles  is  kept  to  a 
minimum,  during  installation  and  servicing  we  recommend  that  a  HEPA 
filtered  vacuum  cleaner  is  used  to  remove  any  dust  accumulated  in  and 
around  the  appliance  before  and  after  working  on  the  appliance.  We 
recommend  that  any  replaced  items  are  not  broken  up,  but  are  sealed 
within  heavy  duty  polythene  bags  and  clearly  labelled  as  RCF  waste.  RCF 
waste  is  classed  as  a  stable,  non-reactive  hazardous  waste  and  may  be 
disposed  of  at  landfill  sites  licensed  to  accept  such  waste.  Protective 
clothing  is  not  required  when  handling  these  articles  but  we  recommend 
that  the  normal  hygiene  rules  are  followed  of  not  smoking,  eating  or 
drinking  in  the  work  area  and  that  hands  are  washed  before  eating  or 
drinking. 

 

The  appliance  should  be  serviced  at  least  once  a  year  by  a  CORGI 
registered engineer. This is the basic procedure. 

Remove the fascia panel. See section above headed ‘Installing the Fascia Panel’. 

Unscrew the eight nuts and remove the glass door. 

The  ‘Cotswold  Stones’  should  be  taken  off  the  fire.  The  centre  row  should  be 
carefully  lifted  off  the  locating  spikes  and  kept  in  order  so  that  they  can  be 
returned  to  their  original  positions.  All  the  pieces  should  be  shaken  to  remove 
any  debris  but  should  only  be  cleaned  if  absolutely  necessary.  This  should  be 
done  by  gently  brushing  with  a  soft  brush  in  a  direction  away  from  the  person 
and  any  persons  nearby.  This  operation  should  be  performed  outside  facing 
downwind.  

Remove all the black ceramic granules. 

Undo  the  two  screws  holding  the  air  guide  assembly  in  position  a  lift  it  gently 
out  of  the  firebox  making  sure  the  black  ceramic  granules  remain  in  their 
locating  tray.  Remove  the  two  screws  holding  the  burner  and  lift  it  out  of  the 
appliance.  

Thoroughly clean the burner ports. 

The  injector  can  be  inspected  without  removing  the  control  mount  platform  by 
unscrewing it with a small box spanner or pliers.  

To remove the control mount platform; 

 

Disconnect the isolator fitting from the gas control. 

Remove the 2 screws holding the left hand board bracket. Remove the 
bracket and left hand lining board. 

Summary of Contents for Marcello NBFP00RN

Page 1: ...ced Flue Convector MODEL NUMBERS NBFP00RN NBFP00RP INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS D...

Page 2: ...ourself product and it must be installed by a competent person 2 The Installation Instructions must be adhered to without exception 3 The heat from this appliance will cause the wall directly above th...

Page 3: ...lations APPLIANCE DATA NBFP00RN NBFP00RP GAS TYPE NATURAL GAS PROPANE SUPPLY PRESSURE 20mb 37mb HEAT INPUT 4 5 kW Gross 4 25kW Gross GAS RATE 0 43m 3 h 0 16 m 3 h 305g hr INJECTOR SIZE 1 6 mm 1 05 mm...

Page 4: ...structions and ventilation openings are shown below DIMENSION TERMINAL POSITION MINIMUM DISTANCE A Directly below an opening air brick or window etc 300mm B Above an opening air brick opening windows...

Page 5: ...earth shall a Extend through the whole base of the builders opening fireplace recess or beneath the flue box b Project at least 275mm in front of the glass window panel c Project at least 150mm beyond...

Page 6: ...the dwelling Fitting This appliance can be installed either by being fixed directly on to the surface or it can be inset into the inner leaf of a cavity wall Before starting the installation remove th...

Page 7: ...are not concentric and that the inner tube is positioned towards the top of the outer tube Using a 3 5mm diameter drill drill holes through the holes in the flue outer ring and into the outer flue tu...

Page 8: ...porally screw the convector box to the inner wall plate with four M5 screws Place the convector box over the protruding flue pipe and push the box into the hole already cut in the inner leaf of the ca...

Page 9: ...tor box flange Fix the heat exchanger through the convector box flanges to the inner fascia using the M5 bolts supplied Replace the self tapping screws that secure the flue to the wall plate Seal the...

Page 10: ...the gas supply must be turned on by removing the cap from the isolator fitting and unscrewing the plug all the way out Replace the cap making sure that the tab engages with the slot in the top of the...

Page 11: ...11 4 Advise the importance of having the appliance serviced on an annual basis...

Page 12: ...results from your fire we recommend that it be serviced annually 7 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place 8 If you have any reas...

Page 13: ...ger period d Depress control knob A slightly and turn anti clockwise to the ON position The main burner will not operate until this is done The main burner may light depending on the position of Contr...

Page 14: ...the DOWN button on the handset Release when the flame is at the desired height or has gone out Once again the electric motor should be heard moving Control Knob B Cleaning the fire Ensure that the app...

Page 15: ...eating or drinking in the work area and that hands are washed before eating or drinking The appliance should be serviced at least once a year by a CORGI registered engineer This is the basic procedure...

Page 16: ...it and secure with the eight nuts Tighten the nuts evenly Stubborn marks can be removed with steel wool and detergent AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS JOINTS 12 Replac...

Page 17: ...placement the parts list is as follows Part Description Part Number Motorised valve CV 104103 Remote hand control Receiver CV 104413 Pilot Burner NG Model CV 104506 Pilot Burner LPG Model CV 104513 In...

Page 18: ...3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 5th SERVICE Serviced by CORGI No Service Date Signed Com...

Page 19: ...19 B 111770 Issue 2 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com...

Reviews: