Useful tips & recommendations 

 

Once  your  fire  has  been  fitted,  the  following  recommendations  are  made  to 
ensure you enjoy the best results from your purchase; 

1

 

The  installation  of  this  appliance  must  have  been  carried  out  by  a  qualified 
installer  and  in  accordance  with  the  requirements  of  the 

Gas  Safety 

(Installation & Use) Regulations

 

2

 

The  glass  door  and  the  upper  part  of  the  fascia  panel  are  considered  to  be 
working  surfaces  and  as  such  will  become  hot  when  in  use.

 

Care  should  be 

exercised  when  using  the  controls  of  the  appliance  when  it  is  hot.    We  also 
recommend  that  a  fireguard,  conforming  to  BS  6539  or  BS  6778,  be  fitted  for 
the protection of young children, the elderly or infirm. 

3

 

When  new,  any  painted  surfaces  or  ceramic  components  may  produce  a  slight 
odour, but this will completely vanish after a few hours of use.  

The  appliance

  MUST  NOT

  be  used  with  the  front  fascia  panel  in  the  dropped 

down  position  or  with  the  glass  panel  removed.  If  there  is  any  suspicion  of 
damage to the glass the appliance must not be used. 

 

To  obtain  the  best  results  from  your  fire  we  recommend  that  it  be  serviced 
annually. 

These  instructions  are  provided  to  assist  you  to  operate  the  fire  correctly  and 
should be kept in a safe place. 

If  you  have  any  reason  to  suspect  a  gas  leak,  turn  off  the  appliance  at  the 
isolating point and contact your installer. 

Curtains should not be hung above the appliance. 

Operation of the fire 

1

 

The  pilot  flame  heats  the  thermocouple  probe  and  allows  gas  to  flow  to  the 
burners.    If  due  to  pilot  failure,  the  thermocouple  cools,  no  gas  will  flow  to  the 
main burner.  If the fire is turned off or the flames go out, wait for 

AT LEAST 3 

MINUTES

 before attempting to relight the fire. 

2

 

For  convenience  you  will  find  with  the  appliance  a  card  giving  concise  lighting 
instructions, please keep this in a safe place.  

Opening and Closing the Fascia Panel 

CAUTION:  ONLY DO THIS WHEN THE FIRE IS COLD 

To  open  the  fascia  panel  grip  it  at  each  side,  lift  slightly,  pull  outwards  and 
lower. 

This will allow access to the gas control  and to the battery pack-signal receiver 
to light the appliance and change the batteries. 

To  close  the  fascia  grip  it  at  each  side,  lift  fully,  push  forwards  and  release. 
Always grip the fascia at each side where it will be cool and not at the top where 
it may be very hot. 

Summary of Contents for Marcello NBFP00RN

Page 1: ...ced Flue Convector MODEL NUMBERS NBFP00RN NBFP00RP INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS D...

Page 2: ...ourself product and it must be installed by a competent person 2 The Installation Instructions must be adhered to without exception 3 The heat from this appliance will cause the wall directly above th...

Page 3: ...lations APPLIANCE DATA NBFP00RN NBFP00RP GAS TYPE NATURAL GAS PROPANE SUPPLY PRESSURE 20mb 37mb HEAT INPUT 4 5 kW Gross 4 25kW Gross GAS RATE 0 43m 3 h 0 16 m 3 h 305g hr INJECTOR SIZE 1 6 mm 1 05 mm...

Page 4: ...structions and ventilation openings are shown below DIMENSION TERMINAL POSITION MINIMUM DISTANCE A Directly below an opening air brick or window etc 300mm B Above an opening air brick opening windows...

Page 5: ...earth shall a Extend through the whole base of the builders opening fireplace recess or beneath the flue box b Project at least 275mm in front of the glass window panel c Project at least 150mm beyond...

Page 6: ...the dwelling Fitting This appliance can be installed either by being fixed directly on to the surface or it can be inset into the inner leaf of a cavity wall Before starting the installation remove th...

Page 7: ...are not concentric and that the inner tube is positioned towards the top of the outer tube Using a 3 5mm diameter drill drill holes through the holes in the flue outer ring and into the outer flue tu...

Page 8: ...porally screw the convector box to the inner wall plate with four M5 screws Place the convector box over the protruding flue pipe and push the box into the hole already cut in the inner leaf of the ca...

Page 9: ...tor box flange Fix the heat exchanger through the convector box flanges to the inner fascia using the M5 bolts supplied Replace the self tapping screws that secure the flue to the wall plate Seal the...

Page 10: ...the gas supply must be turned on by removing the cap from the isolator fitting and unscrewing the plug all the way out Replace the cap making sure that the tab engages with the slot in the top of the...

Page 11: ...11 4 Advise the importance of having the appliance serviced on an annual basis...

Page 12: ...results from your fire we recommend that it be serviced annually 7 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place 8 If you have any reas...

Page 13: ...ger period d Depress control knob A slightly and turn anti clockwise to the ON position The main burner will not operate until this is done The main burner may light depending on the position of Contr...

Page 14: ...the DOWN button on the handset Release when the flame is at the desired height or has gone out Once again the electric motor should be heard moving Control Knob B Cleaning the fire Ensure that the app...

Page 15: ...eating or drinking in the work area and that hands are washed before eating or drinking The appliance should be serviced at least once a year by a CORGI registered engineer This is the basic procedure...

Page 16: ...it and secure with the eight nuts Tighten the nuts evenly Stubborn marks can be removed with steel wool and detergent AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS JOINTS 12 Replac...

Page 17: ...placement the parts list is as follows Part Description Part Number Motorised valve CV 104103 Remote hand control Receiver CV 104413 Pilot Burner NG Model CV 104506 Pilot Burner LPG Model CV 104513 In...

Page 18: ...3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 5th SERVICE Serviced by CORGI No Service Date Signed Com...

Page 19: ...19 B 111770 Issue 2 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com...

Reviews: