Verine Fontana Compact BF User Instructions Download Page 6

NOTE : THIS APPLIANCE IS DESIGNED TO WORK SAFELY AND

EFFECTIVELY DURING ADVERSE WEATHER CONDITIONS. HOWEVER,

DURING SUCH TIMES FLAME DISTURBANCE MAY BE NOTICED. THIS IS

NORMAL AND DOES NOT EFFECT OR IMPAIR THE SAFETY OF THE

APPLIANCE.

CLEANING

WARNING :

Before attempting any cleaning operation ensure that the fire has

been allowed to fully cool.

CLEANING THE TRIM AND PAINTED METAL PARTS

The extruded aluminimum trim that is supplied for use with this product must be

gently cleaned with a damp cloth only.

Abrasive cleaners, chemical cleaning

agents or any type of polish must never be used as damage to the paint may

result.

CLEANING THE FUEL BED

We do not recommend cleaning the fuelbed other than at annual service intervals.

If carbon or soot accumulates on the logs, this should be removed by carefully

brushing the fuelbed using a soft brush. For instructions on how to remove the

glass panel please see page 7.

The log set is made from a form of refractory

ceramic fibre and should be handled carefully to avoid generating dust, as

this may be harmful if inhaled. As with some fibrous materials, handling

fibrous materials without gloves could cause skin irritation.

The fuelbed should never be washed or exposed to any cleaning agents or

water

.

Any damaged parts must be replaced by contacting your dealer, whose details

may be found on the BFM Europe website, address on the rear page. The log

set must only be replaced with a genuine replacement and the fire must never be

run with a different log set fitted.

The log set must be carefully reassembled as stated in pages 8-12.

6

Summary of Contents for Fontana Compact BF

Page 1: ...ATER User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No NHBL RN is for use on Natural Gas G20 at a supply pressur...

Page 2: ...ve the top of the appliance and the depth of the shelf does not exceed 150mm The fire may be installed below combustible shelves which exceed 150mm deep providing that the clearance above the fire is...

Page 3: ...3 2002 Fireguards for use with gas heating appliances Servicing should be carried out annually by a competent person such as a GAS SAFE registered engineer It is a condition of Verine Fires guarantee...

Page 4: ...he control knob further anticlockwise the piezo igniter will cause a spark at the pilot to light the pilot burner Once the pilot burner is lit hold the control knob depressed for approximately 10 seco...

Page 5: ...e main burner off at this point a clicking noise will be heard from the motor Fig 2 If the remote does not work first check the LED in the top left hand corner is illuminating when the button is press...

Page 6: ...er than at annual service intervals If carbon or soot accumulates on the logs this should be removed by carefully brushing the fuelbed using a soft brush For instructions on how to remove the glass pa...

Page 7: ...ions below for removal and re fitting The glass panel should be cleaned gently with a soft damp cloth and glass cleaner DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO CLEAN THE GLASS PANEL WHEN THE APPLIAN...

Page 8: ...burner flame strip Ensure that the fuel bed Log A is located centrally in the firebox and that the front edge is parallel with the rear face of the burner flame strip as shown below in Fig 6 Fig 6 IMP...

Page 9: ...fork of the log into the upturn in the base plate Fig 7 d Fit Log C into position on left hand side of the fuel bed base log A as shown below in Fig 8 using the groove in Log A as a guide for placeme...

Page 10: ...uel bed base log A as shown below in Fig 10 using the groove in the centre of Log A as a guide for placement Fig 10 IMPORTANT NOTE HAVING FITTED THE GRAVEL MATERIAL IN THE BASE OF THE COMBUSTION CHAMB...

Page 11: ...appliance before and after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within a heavy duty polythene bag clearly labell...

Page 12: ...el must locate onto the base of the fire If the stainless steel insert is required this is optional to fit then push it into the front panel at this stage Fig 11 b Fit the front panel and optional sta...

Page 13: ...B B 105680 Log Form C B 105690 Log Form D B 105700 Log Form E B 105710 REPLACING THE BATTERIES IN THE HANDSET a Remove the old 9V battery by removing the cover on the back of the handset b Refit new...

Reviews: