ABOUT YOUR NEW FONTANA COMPACT BF ROOM HEATER

The Verine Fontana Compact log effect balanced flue room heater incorporates a

unique and highly developed fuel bed which gives the realism of a loose log layout

combined with realistic flames and glow. The use of durable hard ceramic material

in the construction of the fuelbed components ensures long and trouble free

operation.

When first using the new fire a slight smell may be noticed. This is due to small

deposits of oil on the firebox, but will soon disappear

Please take the time to fully read these instructions as you will then be able to

obtain the most effective and safe operation of your fire.

DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO USE THIS APPLIANCE

IF THE GLASS PANEL IS BROKEN OR HAS BEEN REMOVED.

IMPORTANT SAFETY INFORMATION

WARNING : This appliance has a hot surface and as with all heating

appliances a fireguard should be used for the protection of children, the

elderly and infirm. Fireguards should conform to B.S. 8423 : 2002

(Fireguards for use with gas heating appliances).

Servicing should be carried out annually by a competent person such as a

GAS SAFE registered engineer. It is a condition of Verine Fires guarantee

schemes that this is carried out by a competent person i.e

a GAS SAFE registered Engineer in accordance with these servicing notes

The service should include visually checking the appliance, flue terminal and

fireplace and inspection of the flue pipe seals, replacing as necessary.

The condition of the ceramic log set should be checked and

if necessary the

whole unit should be replaced with a genuine replacement set.

After any servicing work a gas tightness check must always be carried out.

Any debris or deposits should be removed from the log set from time to time. This

may be carried out by referring to the cleaning section as described later in this

book.

Only the fuelbed components as supplied must be used and complete and

genuine replacements must be used.

Always keep furniture and combustible materials well clear of the fire and never

dry clothing or items either on or near to the fire. Never use aerosols or

flammable cleaning products near to the fire when it is in use.

3

Summary of Contents for Fontana Compact BF

Page 1: ...ATER User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No NHBL RN is for use on Natural Gas G20 at a supply pressur...

Page 2: ...ve the top of the appliance and the depth of the shelf does not exceed 150mm The fire may be installed below combustible shelves which exceed 150mm deep providing that the clearance above the fire is...

Page 3: ...3 2002 Fireguards for use with gas heating appliances Servicing should be carried out annually by a competent person such as a GAS SAFE registered engineer It is a condition of Verine Fires guarantee...

Page 4: ...he control knob further anticlockwise the piezo igniter will cause a spark at the pilot to light the pilot burner Once the pilot burner is lit hold the control knob depressed for approximately 10 seco...

Page 5: ...e main burner off at this point a clicking noise will be heard from the motor Fig 2 If the remote does not work first check the LED in the top left hand corner is illuminating when the button is press...

Page 6: ...er than at annual service intervals If carbon or soot accumulates on the logs this should be removed by carefully brushing the fuelbed using a soft brush For instructions on how to remove the glass pa...

Page 7: ...ions below for removal and re fitting The glass panel should be cleaned gently with a soft damp cloth and glass cleaner DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO CLEAN THE GLASS PANEL WHEN THE APPLIAN...

Page 8: ...burner flame strip Ensure that the fuel bed Log A is located centrally in the firebox and that the front edge is parallel with the rear face of the burner flame strip as shown below in Fig 6 Fig 6 IMP...

Page 9: ...fork of the log into the upturn in the base plate Fig 7 d Fit Log C into position on left hand side of the fuel bed base log A as shown below in Fig 8 using the groove in Log A as a guide for placeme...

Page 10: ...uel bed base log A as shown below in Fig 10 using the groove in the centre of Log A as a guide for placement Fig 10 IMPORTANT NOTE HAVING FITTED THE GRAVEL MATERIAL IN THE BASE OF THE COMBUSTION CHAMB...

Page 11: ...appliance before and after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within a heavy duty polythene bag clearly labell...

Page 12: ...el must locate onto the base of the fire If the stainless steel insert is required this is optional to fit then push it into the front panel at this stage Fig 11 b Fit the front panel and optional sta...

Page 13: ...B B 105680 Log Form C B 105690 Log Form D B 105700 Log Form E B 105710 REPLACING THE BATTERIES IN THE HANDSET a Remove the old 9V battery by removing the cover on the back of the handset b Refit new...