SECTION 1
INFORMATION AND REQUIREMENTS
1.0
APPLIANCE INFORMATION
Natural Gas
LPG
Main injector : (1 off)
1.65mm
1.20mm
Pilot Type - S.I.T.140 Series
Size 27
Size 19
Max. Gross Heat Input :
4.6kW
4.8kW
Min. Gross Heat Input :
3.2kW
3.4kW
Gas Rate :
0.427 m3/hr
0.180 m3/hr
Cold Pressure :
20.0+/-1.0 mbar
37.0+/-1.0 mbar
Ignition :
Push-button Piezo (MC models only)
Ignition :
Electronic (RC & EFC models only)
Electrode Spark Gap :
4.0mm
Weight (without fender) :
25.0 kg inclusive of flue pipe and terminal
Fig 1
3
185mm
285mm Min, 625mm Max with standard flue
duct on MC / RC models. 248mm Min,
588mm Max with standard flue duct on EFC
models. A cost option extended flue duct (part
no. CV-MARLT) can be purchased to increase
this dimension on NG MC / RC models to
1010mm or 973mm on NG EFC models)
120mm
580mm
550mm
150mm