24
3.4.16
Resetting all functions of the remote control. (T10)
Press button T10 to reset all the settings on the remote
control.
This will cancel all the setting of the timer and the
remote control will use the default settings.
In addition, by pressing T10 you will display all possible
indications so that you can verify the proper conditions
of display.
3.4.17
Control of Air Conditioner if remote is not available
If you lose the remote control unit, or the batteries are
dead or it is not working for any other reason, you can
still control the air conditioner in the automatic mode
using the microswitch on the console, that is the same
switch that has to be used to reset the clogged filter
alarm light.
To do this, proceed as follows:
-
Make sure the red filter alarm LED is not on.
If it is on, clean the filters and reset the indicator light
as described in paragraph 3.5.1
Use a sharp object to press the microswitch located
under the hole in the console.
-
The air conditioner will function in “AUTO” mode.
To restore normal operation under the control of the
remote handset, you need only to give any command
with the handset when it becomes available again.
3.5
MAINTENANCE
Your air conditioner has been designed to reduce
operations of routine maintenance to a minimum and
ensure that they can be performed easily by any user.
The only operations required are the three types of
cleaning illustrated below.
3.5.1
Cleaning the air filter
To ensure effective internal air filtration and satisfactory
operation of your air conditioner, the air filter has to be
cleaned periodically.
The need to perform this important operation is signalled
by a red LED lighting up on the control panel (fig 26)
The filter is located on the front of the air intake grille
on the back of the machine.
To remove it, press on the two fastening hooks and pull
the filter toward you (fig 42).
Wash the filter by forcing a jet of water in the opposite
direction from that of the dust.
In case of dirt that is hard to remove you may need to
soak the filter first in a solution of water and mild
detergent.
Before replacing the filter shake any excess water from
it. The last part of the operation consists of briefly
pressing with a sharp object the microkey located on the
control panel.
The red LED goes off and lights up again after the air
conditioner has been in operation for a few days.