![Veridt 900W2026 Installation Manual Download Page 5](http://html1.mh-extra.com/html/veridt/900w2026/900w2026_installation-manual_1003913005.webp)
VERIDT INC · Middleton, WI 53562
5
www.veridt.com
2022
• T E C H N I C A L N O T E •
Verify Identify
Introduction to Stealth Series:
Stealth Bio
PN 900W2030
Stealth Dual
PN 900W2036
Stealth Lite
PN 900W2037
Stealth
PN 900W2026
Stealth Lite
PN 900W2027
Biometrics
Fingerprint
No
No
No
No
Card Read Interface
Status Indicators
Yes + Access Light
Bar
Yes + Access Light
Bar
Access Light Bar Yes + Access Light
Bar
Access Light Bar
Footprint
7” x 3”
(18 cm x 7.5cm)
FIPS 201 APL Number 10031 & 10092
10032 & 10093
10033 & 10094
10034 & 10095
10035 & 10096
Keypad
d
No
Illuminated with
tactile feedback
No
Dual: Contactless & Contact
Dual: Contactless
5.5” x 3” (14 cm x 7.5cm)
Illuminated with tactile feedback
General Installation Information
Veridt Stealth series readers are designed to be operated as a Class 1 access control system component for
use without requirements to withstand a destructive attack. A Tamper Indicator switch is available to provide a
supervisory indication to the PACS in the event the reader is removed from its installed location.
Veridt Stealth series readers are designed to meet the requirements of the National Electrical Code for Class 2
systems and are intended to be used with UL294 listed control equipment.
The installation of these readers, and the materials used for installation, should be in accordance with the location
requirements and the wiring methods defined by the National Electrical Code for Class 2 systems. Connect only to
a Listed Access Control/Burglary power-limited power supply.
The connections of the reader pigtail to the wiring system must ensure a thoroughly good physical connection
without damaging the conductors and should be made by means of pressure connectors or pressure splices
suitable for 18-gauge stranded copper wire.
Installation should be performed by qualified individuals who have the skills and knowledge related to the
installation and operation of the equipment and have received the proper safety training to recognize and avoid