Veridt 900W2026 Installation Manual Download Page 1

VERIDT INC  ·   Middleton, WI 53562

www.veridt.com

2022

• T E C H N I C A L   N O T E •

Verify    Identify

©Copyright 2022 Veridt, Inc. All rights reserved. Specifications subject to change without notice. Veridt, Stealth, and MultiMode are 

trademarks of Veridt. All other brands or product names are the trademarks or registered trademarks of their respective holders.

For Veridt Readers with 
Base Part Number:

900W2026

900W2027

900W2030
900W2036

900W2037

#121

Installation Guide

Stealth Readers

Summary of Contents for 900W2026

Page 1: ...ved Specifications subject to change without notice Veridt Stealth and MultiMode are trademarks of Veridt All other brands or product names are the trademarks or registered trademarks of their respect...

Page 2: ...8 Low Voltage Power Drop 8 Reader to EWAC EWAC to Panel EWAC to Power Supply Network 9 Reader Interface Signals 9 PACS Wiring Diagrams 10 AMAG Wiegand 10 Galaxy Wiegand 10 Gallagher OSDP 10 Genetec O...

Page 3: ...rmation 20 List of Figures Figure 1 Stealth Series 6 Figure 2 Stealth Series Mounting Plates 8 Figure 3 Stealth Series Grounding Reader To Panel Reader Panel To Power Supply 9 Figure 4 Stealth Series...

Page 4: ...warranty Installation should be performed by qualified individuals who have the skills and knowledge related to the installation and operation of the equipment These individuals must have received the...

Page 5: ...y indication to the PACS in the event the reader is removed from its installed location Veridt Stealth series readers are designed to meet the requirements of the National Electrical Code for Class 2...

Page 6: ...d registered card and denying access to an invalid or non registered card Pre Installation Environmental The Veridt Stealth series readers are sealed to keep the reader from exposure to ambient enviro...

Page 7: ...completely concealed The depth measurement includes that additional dimensional requirement of approximately 0 35 inches The Stealth series reader mounting plate can be mounted to a single gang box o...

Page 8: ...feet 1 755 feet DC 300 mA 72 feet 113 feet 198 feet 289 feet 459 feet 732 feet 1 169 feet DC 400 mA 54 feet 85 feet 148 feet 216 feet 344 feet 549 feet 877 feet DC 500 mA 43 feet 68 feet 119 feet 173...

Page 9: ...Wire Colors and Signals Pin Color Connection 1 Pink Not Used I O 2 Brown LED Access Granted 3 White Wiegand D1 4 Yellow RS 485 Data 4 wire TX 5 Gray w White Stripe RS 485 RX 4 wire 6 Black Ground 7 Re...

Page 10: ...lor 600 Series Board Ground Black GND 12V DC Red 12V Access Granted Brown LED Wiegand 0 Green 0 Wiegand 1 White 1 RS485 Blue B RS485 Yellow A Ground Black Ground Gallagher OSDP See also Open Supervise...

Page 11: ...th Reader Wire Color MX 1 Label Ground Black GND 12V DC Red 12V Access Granted Brown LED Wiegand 0 Green D0 Wiegand 1 White D1 JCI Wiegand Stealth Reader Wire Color RDR2SA Label Ground Black GND 12V D...

Page 12: ...s Granted Brown Green LED Wiegand 0 Green D0 Wiegand 1 White D1 Software House iStar Edge Wiegand Stealth Reader Wire Color iStar Edge Label Ground Black GND 12V DC Red Power Access Granted Brown Gree...

Page 13: ...y w white stripe RS 485 Rx Orange No Connection Software House Active Mode Change Stealth Wire Color Signal Black Ground Green Wiegand 0 White Wiegand 1 Orange Tamper Switch Brown Access Granted Grey...

Page 14: ...lth Standard Serial RS 485 Wire Color Signal Black Ground Blue RS 485 Yellow RS 485 Orange Tamper Switch Red 12V DC OSDP Wiring of Tamper Switch For OSDP applications connect the Tamper Switch signal...

Page 15: ...ve adequate power both reader and the EWACS Use an appropriately sized power supply for the PACS panel For example for an eight door panel the power supply must be rated for at least 6 A apply a 50 pe...

Page 16: ...supply 1 Start the Lantronix Device lnstaller The application should display a screen like the one shown here The two Lantronix devices depict two different EWAC board 2 At the main window select the...

Page 17: ...display 8 If the IP address is incorrect turn off BOOTP Client and the DHCP Check and enter the correct static IP address 9 Next select the Tunnel option click the button on the Tunnel 1 Connect Mode...

Page 18: ...shooting Please have the following information available before calling Veridt Table 3 Reader Information Serial Number Date of Manufacture Month Year Voltage Current Reader from Power Distance Power...

Page 19: ...ll include the following or similar statement placed in a prominent location in the text of the manual Note This equipment has been tested and found to comply with the limits for a Class A digital dev...

Page 20: ...l of traffic through portals of a protected area by identifying the requestor and approving entrance or exit Document Control Date Revisions Description July 19 2021 Rev 07 New PAM wiring colors Febru...

Reviews: