Pressure Relief Procedure
Follow the Pressure ReliefProcedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is relieved manually. To help prevent serious
injury from pressurized fluid, such as splashing
in the eyes or on skin, follow the Pressure Relief
Procedure when you stop pumping and before you
clean, check, or service the equipment.
1. Remove power from the system.
2. Open the dispensing valve, ifused.
3. Open the fluid drain valve (L), ifused, to relieve
fluid pressure. Have a container ready to catch
the drainage.
4. Shut off the air supply to the pump.
5. Back out center section regulator to relieve air
pressure in center section.
Pump Shutdown
At the end of the work shift and before you check,
adjust, clean, or repair the system, follow the
Pressure ReliefProcedure, page 19
.
859.0769
19