background image

Warnings

WARNING

WARNING

WARNING

THERMAL

THERMAL

THERMAL EXPANSION

EXPANSION

EXPANSION HAZARD

HAZARD

HAZARD

Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure
due to the thermal expansion. Over-pressurization can result in equipment rupture and serious
injury.

• Open a valve to relieve the fluid expansion during heating.
• Replace hoses proactively at regular intervals based on your operating conditions.

PLASTIC

PLASTIC

PLASTIC PARTS

PARTS

PARTS CLEANING

CLEANING

CLEANING SOLVENT

SOLVENT

SOLVENT HAZARD

HAZARD

HAZARD

Many solvents can degrade plastic parts and cause them to fail, which could cause serious
injury or property damage.

• Use only compatible water-based solvents to clean plastic structural or pressure-containing

parts.

• See Technical

Technical

Technical Data

Data

Data in this and all other equipment instruction manuals. Read fluid and

solvent manufacturer’s Safety Data Sheet (SDS) and recommendations.

TOXIC

TOXIC

TOXIC FLUID

FLUID

FLUID OR

OR

OR FUMES

FUMES

FUMES HAZARD

HAZARD

HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin,
inhaled, or swallowed.

• Read Safety Data Sheet (SDS) to know the specific hazards of the fluids you are using.
• Route exhaust away from work area. If diaphragm ruptures, fluid may be exhausted into

the air.

• Store hazardous fluid in approved containers, and dispose of it according to applicable

guidelines.

BURN

BURN

BURN HAZARD

HAZARD

HAZARD

Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid
severe burns:

• Do not touch hot fluid or equipment.

PERSONAL

PERSONAL

PERSONAL PROTECTIVE

PROTECTIVE

PROTECTIVE EQUIPMENT

EQUIPMENT

EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury,
including eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective
equipment includes but is not limited to:

• Protective eyewear, and hearing protection.
• Respirators, protective clothing, and gloves as recommended by the fluid and solvent

manufacturer.

819.0777

5

Summary of Contents for VA15DP-AC TF TF TN OD

Page 1: ...ts 819 0777 Rev C EN Important Important Important Safety Safety Safety Instructions Instructions Instructions Important Important Important Safety Safety Safety Instructions Instructions Instructions Read all warnings and instructions in this manual Save Save Save these these these instructions instructions instructions ...

Page 2: ...ge 6 Overview 7 Installation 8 General Information 8 Grounding 9 Parts Lists 10 Dimensions 12 Technical Data 13 Notes 14 Customer Services Guarantee 15 Related Related Related Manuals Manuals Manuals Manual Number Title 819 6900 Air Operated Diaphragm Pumps 2 819 0777 ...

Page 3: ... Eliminate all ignition sources such as pilot lights cigarettes portable electric lamps and plastic drop cloths potential static arc Ground all equipment in the work area See Grounding Grounding Grounding instructions Keep work area free of debris including solvent rags and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use onl...

Page 4: ...etailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equipment daily Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sur...

Page 5: ...et SDS and recommendations TOXIC TOXIC TOXIC FLUID FLUID FLUID OR OR OR FUMES FUMES FUMES HAZARD HAZARD HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read Safety Data Sheet SDS to know the specific hazards of the fluids you are using Route exhaust away from work area If diaphragm ruptures fluid may be exhausted into the air S...

Page 6: ... TF TF TB OD 819 0750 Poly 819 0756 Poly VA15 Acetal NPT 810 0876 VA15DP AC TF TF TN OD 819 0751 Acetal 819 0754 SST VA15 Acetal BSPT 810 0881 VA15DP AC TF TF TB OD 819 0751 Acetal 819 0754 SST VA15 Acetal NPT 810 0876 VA15DP AC TF TF TN OD 819 0751 Acetal 819 0755 Aluminum VA15 Acetal BSPT 810 0881 VA15DP AC TF TF TB OD 819 0751 Acetal 819 0755 Aluminum VA20 Aluminum NPT 810 0877 VA20AP AC SP SP ...

Page 7: ...rview Overview Overview Overview Base kit and tube with offset mounting plate SST only Base kit and tube with standard mounting plate plastic or aluminum Representative package with pump mounted 819 0777 7 ...

Page 8: ...n the drum is low These units should be used only only only on drums positioned on flat level surface Uneven or slanted surfaces could cause the drum to tip over Do not relocate a drum with the unit mounted in the bung hole When the unit is mounted the center of gravity is too high for stability when moving the drum NOTICE NOTICE NOTICE The bung adaptor 8 has 63 mm 2 5 in of adjustment to accommod...

Page 9: ...lode Improper grounding can cause electric shock Grounding provides an escape wire for the electric current Always Always Always ground the entire fluid system as described below Pumps with Polypropylene Polypropylene Polypropylene fluid sections are not not not conductive Never Never Never use a nonconductive polypropylene pump with flammable fluids Follow your local fire codes 819 0777 9 ...

Page 10: ...t SST 4 4 8 5 ADAPTOR bung 1 1 1 6 RETAINER o ring 1 1 1 PLATE mounting offset 1 7 PLATE mounting 1 1 ADAPTOR bung polypropylene 1 ADAPTOR bung acetal 1 8 ADAPTOR bung stainless steel 1 9 GASKET 1 1 1 10 RIVET pop 2 2 2 11 PLATE designation 1 1 1 12 FITTING street elbow npt 1 13 NUT hex jam 4 14 NUT full hex regular 4 Tubes Tubes Tubes Ref Ref Ref Description Description Description Tube part numb...

Page 11: ...Parts Lists Offset mounting plate and street elbow for use with stainless steel pump only 819 0777 11 ...

Page 12: ...ns Dimensions Dimensions Dimensions A 216 mm 8 5 in A 216 mm 8 5 in B 152 mm 6 0 in B 175 mm 6 9 in C Adjustable from 66 mm 2 6 in to 130 mm 5 1 in D Adjustable from 800 mm 31 5 in to 864 mm 34 0 in 12 819 0777 ...

Page 13: ...base and aluminum tube 4 5 lb 2 0 kg Acetal base and SST tube 6 5 lb 2 9 kg SST base and tube 9 5 lb 4 3 kg VA15 polypropylene pump 6 5 lb 2 9 kg VA15 acetal pump 7 8 lb 3 5 kg VA20 aluminum pump 8 5 lb 3 9 kg VA20 SST pump 18 0 lb 8 2 kg Wetted Wetted Wetted Parts Parts Parts Noted in item descriptions Non Non Non wetted wetted wetted parts parts parts materials vary depending on kit epoxy coated...

Page 14: ...Notes Notes Notes Notes 14 819 0777 ...

Page 15: ...ed and shall not exceed the purchase price WARRANTY WARRANTY WARRANTY DISCLAIMER DISCLAIMER DISCLAIMER VERDER has made an effort to illustrate and describe the products in the enclosed brochure accurately however such illustrations and descriptions are for the sole purpose of identification and do not express or imply a warranty that the products are merchantable or fit for a particular purpose or...

Page 16: ... Via Maestri del Lavoro 5 Vazia Rieti ITALY Tel 39 0746 221224 e mail info verder it India India India Verder India Pumps PVT LTD Plot No 3b 3part 11 D 1 Block MIDC Block Chinchwad Pune 411019 INDIA Tel 91 20 64104466 e mail Sales verder co in www verder co in The The The Netherlands Netherlands Netherlands Verder BV Leningradweg 5 NL 9723 TP Groningen THE NETHERLANDS Tel 31 50 549 59 00 Fax 31 50...