background image

Warnings

Warnings

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific
risks. When these symbols appear in the body of this manual or on warning labels, refer back to these
Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout
the body of this manual where applicable.

WARNING

WARNING

WARNING

FIRE

FIRE

FIRE AND

AND

AND EXPLOSION

EXPLOSION

EXPLOSION HAZARD

HAZARD

HAZARD

Flammable fumes, such as solvent and paint fumes, in work

work

work area

area

area can ignite or explode. Paint

or solvent flowing through the equipment can cause static sparking. To help prevent fire and
explosion:

• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and

plastic drop cloths (potential static arc).

• Ground all equipment in the work area. See Grounding

Grounding

Grounding instructions.

• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable

fumes are present.

• Use only grounded hoses.
• Stop

Stop

Stop operation

operation

operation immediately

immediately

immediately if static sparking occurs or you feel a shock... Do not use

equipment until you identify and correct the problem.

• Keep a working fire extinguisher in the work area.
• Route exhaust away from all ignition sources. If diaphragm ruptures, fluid may be exhausted

with air.

Static charge may build up on plastic parts during cleaning and could discharge and ignite
flammable vapors. To help prevent fire and explosion:

• Clean plastic parts only in well ventilated area.
• Do not clean with a dry cloth.
• Do not operate electrostatic guns in equipment work area.

819.0777

3

Summary of Contents for VA15DP-AC TF TF TN OD

Page 1: ...ts 819 0777 Rev C EN Important Important Important Safety Safety Safety Instructions Instructions Instructions Important Important Important Safety Safety Safety Instructions Instructions Instructions Read all warnings and instructions in this manual Save Save Save these these these instructions instructions instructions ...

Page 2: ...ge 6 Overview 7 Installation 8 General Information 8 Grounding 9 Parts Lists 10 Dimensions 12 Technical Data 13 Notes 14 Customer Services Guarantee 15 Related Related Related Manuals Manuals Manuals Manual Number Title 819 6900 Air Operated Diaphragm Pumps 2 819 0777 ...

Page 3: ... Eliminate all ignition sources such as pilot lights cigarettes portable electric lamps and plastic drop cloths potential static arc Ground all equipment in the work area See Grounding Grounding Grounding instructions Keep work area free of debris including solvent rags and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use onl...

Page 4: ...etailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equipment daily Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sur...

Page 5: ...et SDS and recommendations TOXIC TOXIC TOXIC FLUID FLUID FLUID OR OR OR FUMES FUMES FUMES HAZARD HAZARD HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read Safety Data Sheet SDS to know the specific hazards of the fluids you are using Route exhaust away from work area If diaphragm ruptures fluid may be exhausted into the air S...

Page 6: ... TF TF TB OD 819 0750 Poly 819 0756 Poly VA15 Acetal NPT 810 0876 VA15DP AC TF TF TN OD 819 0751 Acetal 819 0754 SST VA15 Acetal BSPT 810 0881 VA15DP AC TF TF TB OD 819 0751 Acetal 819 0754 SST VA15 Acetal NPT 810 0876 VA15DP AC TF TF TN OD 819 0751 Acetal 819 0755 Aluminum VA15 Acetal BSPT 810 0881 VA15DP AC TF TF TB OD 819 0751 Acetal 819 0755 Aluminum VA20 Aluminum NPT 810 0877 VA20AP AC SP SP ...

Page 7: ...rview Overview Overview Overview Base kit and tube with offset mounting plate SST only Base kit and tube with standard mounting plate plastic or aluminum Representative package with pump mounted 819 0777 7 ...

Page 8: ...n the drum is low These units should be used only only only on drums positioned on flat level surface Uneven or slanted surfaces could cause the drum to tip over Do not relocate a drum with the unit mounted in the bung hole When the unit is mounted the center of gravity is too high for stability when moving the drum NOTICE NOTICE NOTICE The bung adaptor 8 has 63 mm 2 5 in of adjustment to accommod...

Page 9: ...lode Improper grounding can cause electric shock Grounding provides an escape wire for the electric current Always Always Always ground the entire fluid system as described below Pumps with Polypropylene Polypropylene Polypropylene fluid sections are not not not conductive Never Never Never use a nonconductive polypropylene pump with flammable fluids Follow your local fire codes 819 0777 9 ...

Page 10: ...t SST 4 4 8 5 ADAPTOR bung 1 1 1 6 RETAINER o ring 1 1 1 PLATE mounting offset 1 7 PLATE mounting 1 1 ADAPTOR bung polypropylene 1 ADAPTOR bung acetal 1 8 ADAPTOR bung stainless steel 1 9 GASKET 1 1 1 10 RIVET pop 2 2 2 11 PLATE designation 1 1 1 12 FITTING street elbow npt 1 13 NUT hex jam 4 14 NUT full hex regular 4 Tubes Tubes Tubes Ref Ref Ref Description Description Description Tube part numb...

Page 11: ...Parts Lists Offset mounting plate and street elbow for use with stainless steel pump only 819 0777 11 ...

Page 12: ...ns Dimensions Dimensions Dimensions A 216 mm 8 5 in A 216 mm 8 5 in B 152 mm 6 0 in B 175 mm 6 9 in C Adjustable from 66 mm 2 6 in to 130 mm 5 1 in D Adjustable from 800 mm 31 5 in to 864 mm 34 0 in 12 819 0777 ...

Page 13: ...base and aluminum tube 4 5 lb 2 0 kg Acetal base and SST tube 6 5 lb 2 9 kg SST base and tube 9 5 lb 4 3 kg VA15 polypropylene pump 6 5 lb 2 9 kg VA15 acetal pump 7 8 lb 3 5 kg VA20 aluminum pump 8 5 lb 3 9 kg VA20 SST pump 18 0 lb 8 2 kg Wetted Wetted Wetted Parts Parts Parts Noted in item descriptions Non Non Non wetted wetted wetted parts parts parts materials vary depending on kit epoxy coated...

Page 14: ...Notes Notes Notes Notes 14 819 0777 ...

Page 15: ...ed and shall not exceed the purchase price WARRANTY WARRANTY WARRANTY DISCLAIMER DISCLAIMER DISCLAIMER VERDER has made an effort to illustrate and describe the products in the enclosed brochure accurately however such illustrations and descriptions are for the sole purpose of identification and do not express or imply a warranty that the products are merchantable or fit for a particular purpose or...

Page 16: ... Via Maestri del Lavoro 5 Vazia Rieti ITALY Tel 39 0746 221224 e mail info verder it India India India Verder India Pumps PVT LTD Plot No 3b 3part 11 D 1 Block MIDC Block Chinchwad Pune 411019 INDIA Tel 91 20 64104466 e mail Sales verder co in www verder co in The The The Netherlands Netherlands Netherlands Verder BV Leningradweg 5 NL 9723 TP Groningen THE NETHERLANDS Tel 31 50 549 59 00 Fax 31 50...

Reviews: