Section 4
General Maintenance
Controller Error Codes
The following Common Error Codes for the heat pump units will be displayed on the
controller panel:
Common Error Code
NAME
CODE
NAME
Compressor high pressure and/or
faulty switch
15E
Faulty inlet water temperature sensor
Compressor low pressure and/or
faulty switch
16E
Faulty Evaporator (heating) pipe sensor
ller communication
18E
Abnormal compressor discharge temperature and/or
Faulty compressor discharge temperature sensor
password control
21E
Ambient temperature too low and/or Faulty ambient
temperature sensor
CODE
05E
06E
09E
Contro
11E
Installer
12E
Compressor high discharge
temperature
29E
Faulty compressor suction temperature sensor
Inspection and Service
Venus
domestic heat pump water heaters are designed and built to provide long life
performance, when installed and operated properly under normal conditions. Periodic
inspections are important to keep your heat pump running safely and efficiently.
Owner Inspection
Venus
recommends that inspections on heat pumps are done frequently, especially after
abnormal weather conditions. The following basic guidelines are suggested for your
inspection:
1 Make sure the front of the unit is accessible for future service.
2. Keep the top and surrounding areas of the heat pump clear of debris.
3.
Keep all plants and shrubs trimmed and away from the heat pump especially the
area before the fan.
4. Keep lawn sprinklers from spraying on the heat pump to prevent corrosion and
damage.
5.
Ensure that the ground wire is always properly connected.
6. The f
ilter must be maintained on a regular basis in order to ensure clean and
healthy water to protect the heat pump from damaging.