R
the compressor when to re-start until desired temperature is reached. (3~18°C
(37.4~64.4°F) default: 5°C (37.4°F)). For example, set water temp. = 25°C (77°F), L2 =
5°C (41°F), the compressor will stop at 25°C (77°F) and re-start at 20°C (68°F)
L4-
Desired water temperature limit (30~99°C (86~210.2°F) default: 60°C (140°F))
L5-
allowed electric heating ambient temperature (0~35°C (32~), default: 7°C (44.6°F),
where 0°C (32°F) means no electric heating).
L9-
Two speeds wind temp control the fan motor. (10°C -45°C (50°F~113°F), default:
45°C (113°F)) (Not Applicant)
H1-
defrosting period (20~99 minutes default: 45 minutes)
H2-
defrosting start temperature (1~-15°C (33.8~5°F) default: -1°C (30.2°F))
H3-
defrosting time (5~20miniutes default: 8 minutes)
H4-
defrosting exiting temperature (1~40°C (33.8~104°F), default: 20°C (68°F))
P1-
electronic expansion valve regulation cycle (20~180 seconds, default: 60 seconds)
P2-
degree of super heat (-8~15°C
(
17.6~59°F
)
, default 0°C
(
32°F
Z)
)
P3-
allowed discharge temperature (70~135°C (158~275°F), default: 92°C (197.6°F))
P4-
expansion valve opening as four-way valve is defrosting (6~55°C (42.8~), default:
32 °C (89.6°F))
P5-
expansion valve minimum opening (6~30°C (42.8~86°F), default: 15°C (57°F))
P6-
super heat compensation (0~12 default: 4)
Note: If the controller is chosen with electronic expansion valve not used (the toggle
switch 3 on controller PC Board is on OFF.), it doesn’t display P1-P6 when setting.
4. Clock setting:
Press the
“timer” key for more than 8 seconds until an audible tone is heard and the
“timer” symbol disappears. The hour value is flashing and can be adjusted by pressing
“up”
and
“down”
keys. Press the “timer” key for minute adjustment and repeat as
previous. Press the “timer” key to exit.
5. Timer setting:
The heat pump consists of two separate timing functions. Timer 01 and 02 are used to
set the ON/OFF times of the heat pump within 24 hour period.
15