Venue Lighting Effects LED PAR 38 User Manual Download Page 5

www.venuelightingeffects.com

OPERATING INSTRUCTIONS

Operating Modes:
You can use the LED PAR 38 in four ways:
• Sound-Active mode - Reacts to sound, chasing through the built-in programs.
• Auto Mode - Automatically chases through the different colors. 
• RGB Mode - Projects a single static color.
•  DMX control mode - This function will allow you to control each individual fixture with a standard  

DMX 512 controller.

Sound Active Mode:
In this mode the LED PAR 38 will react to sound and chase through the different colors.
1. Plug the fixture in and put DIP switch #10 in the “ON” position.
2. The fixture will now be controlled by sound.

Auto Mode:
1. Plug the fixture in and put DIP switches #9 and #10 in the “ON” position.
2. Adjust the speed by adjusting DIP switches #1 through #7. 

RGB Mode:
1. Plug the fixture in and put DIP switches #8, #9, and #10 in the “ON” position.
2.  DIP switch #1 alone will project Red at 25% intensity, DIP switch #2 alone will project Red at 50% intensity. Combine 

DIP switches #1 & #2 and Red will be projected at 100% intensity.  
 
DIP switch #3 alone will project Green at 25% intensity, DIP switch #4  alone will project Green at  
50% intensity. Combine DIP switches #3 & #4 and Green will be projected at 100% intensity. 
 
DIP switch #5 alone will project Blue at 25% intensity, DIP switch #6 alone will project Blue at 50% intensity. Combine 
DIP switches #5 & #6 and Blue will be projected at 100% intensity. 

DMX Mode:
Operating through a DMX controller gives the user the freedom to create their own programs tailored to their  
individual needs. This function also allows you to use your fixtures as spotlights.
1. The LED PAR 38 uses six DMX channels to operate.
2.  To run your fixture in DMX mode, plug in the fixture via XLR connections to any standard DMX controller. 
3. Set your desired DMX address following the set-up specifications that came with your DMX controller. 

Page 5

Summary of Contents for LED PAR 38

Page 1: ...LED PAR 38 USER MANUAL www venuelightingeffects com...

Page 2: ...r serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your warranty PLEASE recycle the shipping carton whenever possible GENERAL INSTRUCTIONS To optimize the perf...

Page 3: ...a that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only Use of this p...

Page 4: ...ix channel DMX unit The DMX address is set on the back panel of the Venue LED PAR 38 Your unit and your DMX controller require a standard 3 pin XLR connector for data input and data output Figure 1 If...

Page 5: ...in the ON position 2 DIP switch 1 alone will project Red at 25 intensity DIP switch 2 alone will project Red at 50 intensity Combine DIP switches 1 2 and Red will be projected at 100 intensity DIP sw...

Page 6: ...ernal optical lenses periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside case 2 Clean the external optics with glass cleaner and a soft cloth eve...

Page 7: ...l owner from the date of purchase Retailer and manufacturer shall not be liable for damages based upon inconvenience loss of use of product loss of time interrupted operation or commercial loss or any...

Page 8: ...onvenience receptacles and the point where they exit from the apparatus Do not break the ground pin of the power supply cord 11 Only use attachments specified by the manufacturer 12 Use only with the...

Reviews: