On
Off
3S
15S
On
Off
On
Off
On
Off
Auto
Manu
AL1
Timer
Vib
AL2
Light
Dimmer
Tone
Volume
Show Calendar
Press the calendar button once, the display will show the calendar for 10 seconds.
Dimmer
Press the dimmer button to select the brightness of the display
Alarm 1 On/Off (clock alarm 1)
Slide the AL1 switch to on or off position. When Alarm 1 is on the alarm1 indicator will light up
Alarm 2 On/Off (clock alarm 2)
Slide the AL2 switch to on or off position. When Alarm 2 is on the alarm2 indicator will light up.
Timer
Slide the timer switch to select the duration of the relay output and 12V output .
Light On/Off
Slide the master light switch to on or off flasher light.
Vibrator On/Off
Slide the Vib master switch to turn on or off vibrator. This is a master switch.
Dimmer Mode
Auto: The LED display dims automatically in the dark .
Manual: Adjust the LED display brightness by pressing the dimmer button.
Tone Adjust
Slide the tone lever to adjust the tone of the beep
sound alert (Sound number 32).
Volume Control
Slide the volume to adjust master sound volume.
Other Setting
Outlet and inlet
DC Jack :
Main power 12V 1A input.
Dimmer
Calendar
Snooze/Stop
Press confirm button to set vibration on or off. Press Up to turn on the vibrator. Press down to turn off
vibrator.
Press confirm button to set 12V output on or off. Press Up to turn on the 12V output. Press down to turn off
vibrator the 12V output.
Press confirm button to set relay output on or off. Press Up to turn on the relay output. Press down to turn
off vibrator the relay output.
Press confirm button to finishing and goto next zone pairing.
To remove the sensor from the receiver memory (unpair).
Press Mode button five time, The display show
Pair
Press confirm button to entering to pair mode. the display show Zone -1 or Zone:1
Press up or down button to select the zone you want to unpair.
Press and hold the up and down buttons for approx. 3 seconds. The receiver will return a beep tone to
confirm this zone is clear. The display will change to show 'zone - x'. (
'
X
'
is zone number, '-' is indicating this
zone is empty.)
When the zone is paired with sensor the display will show “:” between the “zone” and zone number.
eg. zone: 1.
When the zone is empty, the display will show “-” between the “zone” and zone number. eg. zone- 1.
Ext.
Trigger
Alarm
Out
5V Out
Vib
Out
12V
DC In
Dimmer
Calendar
Snooze/Stop
12V/1A
Ext.
Trigger
Alarm
Out
5V Out
Vib
Out
12V
DC In
Dimmer
Calendar
Snooze/Stop
Ext.
Trigger
Alarm
Out
5V Out
Vib
Out
12V
DC In
Dimmer
Calendar
Snooze/Stop
Ext.
Trigger
Alarm
Out
5V Out
Vib
Out
12V
DC In
Dimmer
Calendar
Snooze/Stop
Alarm System or
Amplifier
Ext.
Trigger
Alarm
Out
5V Out
Vib
Out
12V
DC In
Dimmer
Calendar
Snooze/Stop
Bluetooth receiver
Replace the icon plate
After pairing the sensor/bell pusher, do not forget change the sensor indication icon come withe the sensor.
Please keep the original icon plate for unpair the zone.
Vib Out:
Vibrator connect to this outlet. It provide 12V
output to drive the vibrator.
5V output:
This is a standard USB socket. It provide DC5V / 1A to charge
the mobile device. The charge current depend on the max current of
power adaptor and the mobile device .(max. output current is 1A)
Alarm Out:
This is a audio signal output. It
con connect to the external amplifier or other
alarm system.
Ext. Trigger:
This is a external trigger input. you
can apply a 3-12V DC to trigger this input.
Open the display lens
by nails
Tack out the icon plate and
replace the correct one.
Press the top of the icon
plate to fix it. Cover back
the display lens
Press the bottom of the
icon plate. the top of the
icon plate will go out
NO
NC
+12V-
This receive provide some output terminal for special application.
Normal Open(NO) terminal:
This 2 terminal pin is open circuit normally, It will close circuit when
the receiver be triggered. The duration is depend on the timer switch
setting.
Normal Close (NC) terminal:
This 2 terminal pin is close circuit normally, It will open circuit when the
receiver be triggered. The duration is depend on the timer switch
setting.
Normally open and normally closed can only choose one connection.
(The rating do not exceed
48V/500mA)
12V out terminal:
This 2 terminal pin can provide 12v output to drive some device when
the receiver be triggered. The duration is depend on the timer switch
setting. The device current do not exceed 200mA.
3