WARRANTY
Production meets standard
operating requirements
in
the territory of the USA and Canada.
Manufacturer guarantees normal operation of the
unit
60 months from the
of
subject to the
for
date
resale,
fulfillment of transport, storage, mounting and operation
rules.
If
of sales date is absent warranty period is
proof
calculated from the
.
production date
In case of occurrence of
failure due to faulty
during warranty period
consumer
equipment
, the
has the right to
it.
exchange
the following address:
The unit can be exchanged at
Bodor Vents, LLC DBA: VENTS-US
11013 Kenwood Road Cincinnati, Ohio 45242
Phone: (513)348-3853
e-mail:
Manufacturer is not responsible for damages
resulting from of the unit or by gross mechanical
alteration.
Owner of the unit must follow the manual.
Do not dispose of with other trash.
The units are axial fans designed for extract ventilation
of small and medium size rooms that are heated in winter
time.
Fans are made of white plastic; color of front panel
can be white or metallic.
Delivery set includes:
1. Fan - 1;
2. Screws with plugs - 4;
3. User manual;
4. Packing box.
Fans are compatible with 3 15/16" (100 mm),
4 15/16" (125 mm), and 5 7/8" (150 mm) diameter ducts.
Installation options are own on pic 1.
Fans can be mounted with 4 screws and plugs.
Fans only for wall through installation.
Fans can be mounted in the system with short straight
duct runs (max. length 3 ft). Flexible ducts should be
straight and stretched (max. length 3 ft).
Fans can be used to move air against low pressures (max.
0.03 in WG).
“V”
Models
are supplied with pull-cord switch.
Models
are supplied with adjustable timer with
“T”
delay from 2 min up to 30 min.
Models
are supplied with humidity sensor with
“H”
%
level of operating from 60 up to 90%.
models
motor
“Turbo”
are equipped with higher-power
.
X star
fans are supplied with lightning lamp
(GU10, 120V, 60Hz, 0.3W ).
“K”
fan with a back valve.
.
Input: 120V AC 60Hz
onnection for
D
,
LD
,
LDA,
S
,
X, X
1
are shown on
C
fans
Fig.
3-5, mounting - on Fig. 8-14. Turning the timer and
D, S
are shown on Fig.
himidity sensor of
fans
15-21,
LD, LDA, X X1
on Fig.
for
fans are shown
22-26.
onnection
X
star
are shown on Fig.
C
of
fans
6-7,
.
mounting are shown on Fig. 33-43
Fans are designed for long-term operation without
match
disconnection from network. Air motion must
direction of indicator on the fan case. Fans can be
temperatures between 40 and 170ºF.
operated at ambient
Protection
rating
from access to dangerous parts and
water penetration
of
fans is
IР
34
,
of
D
,
LD
,
LDA
,
S
Х,
X
1
,
X star
fans
is
IР24.
Fan construction is constantly being improved,
and
some models
may
differ slightly from
those
described
in this manual
.
Fan surfaces need to be cleaned regularly from dirt
and dust ( Fig.
27
-
32
for
D
,
LD
,
LDA,
S
,
X, X
1
fans,
Fig.
44
-
49
for
X
star
fans
). Cleaning is made with soft cloth
with the usage of water solution and washing agent.
Ingress of liquid to electric motor must be avoided.
After cleaning the surface must be wiped dry.