USER’S MANUAL

VUT2 200 P
VUE2 200 P
VUTE2 200 P

Heat 

(energy / heat and energy)

 

recovery air handling unit

Summary of Contents for VUE2 200 P

Page 1: ...USER S MANUAL VUT2200P VUE2200P VUTE2200P Heat energy heat and energy recovery air handling unit...

Page 2: ...Unitdesignandoperatinglogic 7 Installationandset up 8 Connectiontopowermains 11 Unitcontrol 12 Technicalmaintenance 14 Troubleshooting 15 Storageandtransportationregulations 15 Manufacturer swarranty...

Page 3: ...e VU_2 200 P heat energy heat and energy recovery air handling unit hereinafter referred to as the unit UNIT MOUNTING AND OPERATION SAFETY PRECAUTIONS Disconnect the unit from power mains prior to any...

Page 4: ...the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during operation Do not direct the air flow produced by the unit towa...

Page 5: ...osive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dus...

Page 6: ...ERALL DIMENSIONS OF THE UNIT MM UNIT TECHNICAL DATA Ventilation mode speed LOW low MED medium MAX maximum Unit supply voltage 50 Hz V 1 230 Maximum fan power W 67 104 142 Fan current A 0 58 0 63 0 68...

Page 7: ...erties of the heat exchanger material the unit drainage is not required Heat recovery minimizes heat losses which reduces the cost of space heating in the cold season Freeze protection The heat exchan...

Page 8: ...ake side equal to 3 air duct diameters on outlet side If the air ducts are too short or not connected protect the unit parts from ingress of foreign objects e g by covering the spigots with a pro tect...

Page 9: ...ust have an opening or a hook to fix the three sided thumbscrews to the unit Remove all the three sided thumbscrews from the unit for suspended mounting by means of belts Then insert them into a mount...

Page 10: ...e at least 3 Before starting the unit fill the system with water and check that the U trap is always filled with water Check for any obstructions to the free flow of water into the sewage system to pr...

Page 11: ...and check the installation The wiring diagram of the unit is shown in the figure below The TS1 thermostat relay in the unit casing provides freeze protection of the heat exchanger during cold season...

Page 12: ...tivation of any connected controls the unit switches to high speed ventilation mode Thermostat Medium speed Low speed Standby mode Two wire control panel NO Thermostat Two wire control panel NO Medium...

Page 13: ...ration mode to the high speed mode The unit will operate in the high speed ventilation mode until the relative humidity falls below the set point Adjust the level of humidity if necessary Any mechanic...

Page 14: ...me dust may accumulate inside the fans and reduce the fan performance and supply air flow Clean the fans with a soft brush or cloth Do not use water aggressive solvents or sharp objects as they may da...

Page 15: ...a dry closed ventilated premise with temperature range from 5 C to 40 C Vapoursorparticleswhichcancausecorrosionordamagetheinsulationorconnectiontightnessarenotallowedinthestorageenvironment Use hois...

Page 16: ...the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual inc...

Page 17: ...nit with the user s manual Customer s Signature VU ___ 2 200 P heat energy heat and energy recovery air handling unit has been connected to power mains pursuant to the requirements stated in the prese...

Page 18: ...V87EN 03...