Vents VUE P3B EC A14 User Manual Download Page 7

www.ventilation-system.com

7

UNIT DESIGN AND OPERATING PRINCIPLE

Supply fan 

Exhaust fan

*Bypass damper 

Extract filter 

Control unit

Temperature sensor 

for heat exchanger freezing protection

Electric lead-ins 

Service side

Access door for  inspection and maintenance 

of the filters and heat exchanger

Cross-power heat exchanger 

Intake filter

**Humidity sensor

Control panel

Power cable with a plug 

The service panel is equipped with a detachable access door with manual bolts for cleaning or replacement of the filters and heat exchanger. The 

control unit is positioned inside the unit casing. The power and the ground cable are to connect to the control unit through the airtight electric lead-in 
in the unit casing side.

The plate enthalpy cross-flow heat exchanger is made of polymerized cellulose.
*The bypass damper is open or closed depending on operation mode of the unit.
**At the request of the customer the unit can be equipped with a humidity sensor. The humidity sensor is purchased separately as an accessory. 

The unit with an installed humidity sensor maintains a set indoor humidity point. As the extract air humidity rises above the set point, the system 
automatically switches to the maximum speed. As the humidity drops down below the set point the unit returns to the previous operation mode. 
Installation and connection of the humidity sensor is carried out on site by the service technician.

 

V146EN_01.indd   7

22.03.2017   10:30:52

Summary of Contents for VUE P3B EC A14

Page 1: ...USER S MANUAL Heat and humidity recovery air handling unit VUE P3B EC A14 V146EN_01 indd 1 22 03 2017 10 30 49...

Page 2: ...ery air handling unit hereinafter referred to as the unit SAFETY REQUIREMENTS Read the user s manual carefully prior to installing and operating the unit Fulfil the user s manual requirements as well...

Page 3: ...with water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not stor...

Page 4: ...ECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN Transported air must not cont...

Page 5: ...14 Unit voltage V 50 60 Hz 1 230 Maximum unit power W 70 84 150 Maximum unit current A 0 6 0 7 1 0 Maximum air capacity m3 h 180 300 400 RPM 1925 2000 3200 Sound pressure level at 3 m distance dB A 32...

Page 6: ...247 480 92 128 25 113 88 VUE 350 P3B EC A14 149 1117 1024 846 754 793 843 277 297 488 109 153 50 88 138 R1 5 OUT OUT OUT IN Rx Tx 86 58 39 21 11 2 86 4 62 3 52 Control panel The sensor panel contains...

Page 7: ...e are to connect to the control unit through the airtight electric lead in in the unit casing side The plate enthalpy cross flow heat exchanger is made of polymerized cellulose The bypass damper is op...

Page 8: ...isturized The water vapour is devaporated from the stale wet air and absorbed with heat exchanger plates The released heat and moisture are transferred to the supply air The transferring of dirt odour...

Page 9: ...fasteners consider the material of the mounting surface as well as the weigh of the unit refer to the Technical Data section Fasteners for unit mounting should be selected by the service technician B...

Page 10: ...ed in the control panel delivery set Then connect the cable to the control panel in compliance with external wiring diagram 4 Install the control panel display and press it to fix Control panel wall s...

Page 11: ...the service side panel of the unit and take it off The unit has an option of connection of additional external controls The unit must be connected to power mains using durable insulated and heat resis...

Page 12: ...to a laptop or to a PC via a USB cable with the Type A and Type B contact sockets The USB cable is not included in the delivery USB Type A USB Type B The software enables editing the unit parameters...

Page 13: ...ne of three speed setting buttons The selected button will be highlighted and the unit switches to the required speed Speed changeover Press the inactive speed setting button once The selected button...

Page 14: ...ce of the filters To maintain the high heat exchange efficiency regular heat exchanger vacuum cleaning using a crevice nozzle is recommended To replace the heat exchanger open the access door and remo...

Page 15: ...rong cable installing Make sure the cable installation is completed according to the requirements stated on page 13 Otherwise install the cable as required STORAGE ANDTRANSPORTATION REGULATIONS Store...

Page 16: ...the user Mismatch of the unit model and the brand name with the information stated on the unit packing and in the user s manual User s failure to ensure timely technical maintenance of the unit Extern...

Page 17: ...N CERTIFICATE Installation Company Stamp The unit has been connected to power mains pursuant to the requirements stated in the present user s manual Company Name Address Phone Number Expert s Full Nam...

Page 18: ...www ventilation system com 18 V146EN_01 indd 18 22 03 2017 10 30 56...

Page 19: ...www ventilation system com 19 V146EN_01 indd 19 22 03 2017 10 30 56...

Page 20: ...V146EN 01 V146EN_01 indd 20 22 03 2017 10 30 56...

Reviews: