11
VKP / VKPI
4D 600x350
VKP
4D 1000x500
Voltage [V]
3~ 400 Δ
3~ 400 Y
3~ 400
Frequency [Hz]
50
60
50
60
50
Power [W]
510
750
380
515
3800
Current [A]
1.41
1.44
0.7
0.93
6.6
Max. air capacity [m
3
/h]
2970
3410
2660
2730
15000
RPM [min
-1
]
1415
1610
1235
1220
1360
Noise level at 3 m [dBA]
64 / 55*
64 / 55*
63 / 55*
63 / 55*
70
Transported air temperature [°C]
-40 +60
-40 +60
-40 +80
-40 +40
-20 +40
Protection rating
IPX4
IPX4
IPX4
* parameter applicable for VKPI fan
VKP / VKPI
VKP / VKPI
2E 400x200
VKP / VKPI 2E
500x250
VKP / VKPI
4E 500x300
VKP / VKPI
4D 500x300
Voltage [V]
1~ 220-240
1~ 220-240
1~ 220-240
3~ 400
Frequency [Hz]
50
60
50
60
50
60
50
60
Power [W]
138
200
305
380
140
165
136
165
Current [A]
0.60
0.88
1.32
1.65
0.57
0.53
0.34
0.53
Max. air capacity [m
3
/h]
930
1070
1720
1850
1700
1620
1380
1620
RPM [min
-1
]
2600
2850
2550
2830
1390
1530
1360
1600
Noise level at 3 m [dBA] 59 / 51*
71/63*
61 / 53* 78 / 67* 53 / 45* 55 / 46* 53 / 45* 55 / 46*
Transported air temperature [°C]
-25 +45
-25 +45
-25 +45 -25 +50 -25 +65 -25 +55
Protection rating
IPX4
IPX4
IPX4
IPX4
VKP / VKPI
4E 600x300
VKP / VKPI
4D 600x300
VKP / VKPI
4E 600x350
Voltage [V]
1~ 220-240
3~ 400
1~ 220-240
Frequency [Hz]
50
60
50
60
50
60
Power [W]
220
310
230
235
470
700
Current [A]
0.9
1.38
0.52
0.53
2.37
3.15
Max. air capacity [m
3
/h]
2470
2510
2530
2630
2950
3515
RPM [min
-1
]
1400
1450
1360
1600
1370
1460
Noise level at 3 m [dBA]
55 / 47*
55 / 57*
53 / 46*
53 / 46*
67 / 59*
68 / 59*
Transported air temperature [°C]
-25 +45
-25 +70
-25 +65
-40 +80
-40 +55
Protection rating
IPX4
IPX4
IPX4