11
The ventilator consists of a telescopic air duct with adjustable length (inner part and outer part), a ventilation unit and an outer ventilation
hood. The inner telescopic part contains one or two air filters, depending on the ventilation model and a ceramic regenerator.
The air filters are designed to purify supply air and prevent foreign object ingress into the regenerator and the fan. The ceramic regenerator
utilises extract air heat energy to warm up supply air flow. The regenerator is equipped with a pull cord inside to facilitate its withdrawal from
the ventilator. The regenerator is installed on an insulating layer used as a sealer as well.
The ventilation unit must be installed on inner side of the wall.
The ventilation unit is equipped with automatic shutters that shut the air duct off during the ventilator standby and prevent air back draft.
TwinFresh S-60 and its modifications are not equipped with automatic shutters.
The outer ventilation hood is used to prevent direct ingress of water and other objects to the ventilator.
Outer ventilation hood
Prevents direct ingress of water and foreign
objects into the ventilator.
1. TwinFresh R-50 and its modifications
2. TwinFresh S-60 and its modifications
3. TwinFresh S1-50 and its modifications
Distance ring
It doubles as a support for filters and a
regenerator in the inner telescopic duct.
Filter
Cleans supply air flow and prevents ingress of
dust and foreign objects into the ventilator.
Prevents soiling of the regenerator.
Air flow rectifier
Prevents air turbulences and reduces noise
level.
Fan
Generates air flow.
Ventilation unit
Generates air flow by means of the fan. The
ventilation unit is covered with a ventilation
grille on inner wall side to prevent ingress of
foreign objects into the fan. The ventilation
unit is equipped with automatic shutters to
back draft prevention. The air shutters open
during the ventilator activation and close
during its shutdown.
Outer air duct
Outer part of the telescopic air duct.
Ceramic regenerator
Utilises extract air heat energy to warm up
supply air flow.
Inner air duct
Inner part of the telescopic air duct.
Decorative front panel
Used for decoration of the ventilator.
Decorative grille
Protects the ventilator from foreign object
ingress from inside.
Internal filter
Cleans supply air flow and prevents ingress of
dust and foreign objects into the ventilator.
Prevents soiling of the regenerator.
1
3
2
TWINFRESH STRUCTURE
AUTOMATIC SHUTTERS OPERATION
Ventilator is off (the automatic shutters are closed)
Ventilator is on (the louver shutters are opened)
DESIGN AND OPERATING LOGIC