Vents KSB 100 K2 User Manual Download Page 3

3

www.ventilation-system.com

THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.

DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC  WASTE.

This unit is not intended for use by persons (including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the unit by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the unit.
The appliance is only to be used with the power supply unit provided with the appliance.

Connection to the mains must be made through a disconnecting device, which is integrated 
into the fixed wiring system in accordance with the wiring rules for design of electrical units, 
and has a contact separation in all poles that allows for full disconnection under overvoltage 
category III conditions.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or 
similarly qualified persons in order to avoid a safety hazard.

CAUTION: In order to avoid a safety hazard due to inadvertent resetting of the thermal cut-
out, this unit must not be supplied through an external switching device, such as a timer, or 
connected to a circuit that is regularly switched on and off by the utility.

Ensure that the unit is switched off from the supply mains before removing the guard.
WARNING: If there are any unusual oscillating movements, immediately stop using the unit and 
contact the manufacturer, its service agent or suitably qualified persons. 
The replacement of parts of the safety suspension system device shall be performed by the 
manufacturer, its service agent or suitably qualified persons.

Fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a 
sufficient strength to withstand 4 times the weight of the appliance.
The mounting of the suspension system shall be performed by the manufacturer, its service 
agent or suitably qualified persons.
The appliance is to be installed so that the blades are more than 2.3m above the floor.
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of 
gas or other fuel-burning appliances.

of its products at any time in order to incorporate the latest technological developments.
Never touch the unit with wet or damp hands.
Never touch the unit when barefoot.

Summary of Contents for KSB 100 K2

Page 1: ...KSB K2 USER S MANUAL Centrifugal duct fan in sound insulated casing...

Page 2: ...observed when installing and operating the unit Disconnect the unit from the power supply prior to any connection servicing maintenance and repair operations Only qualified electricians with a work pe...

Page 3: ...ue to inadvertent resetting of the thermal cut out this unit must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off b...

Page 4: ...us substances toxic substances dust pathogenic germs THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING...

Page 5: ...25 55 25 55 25 55 25 55 25 55 25 55 25 55 25 55 25 55 25 55 25 55 25 55 25 55 Ingress protection rating IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 SEC class C C C C C C H L B B1...

Page 6: ...er on the intake side and 3 air duct diameters on the exhaust side No filters or any other similar devices are allowed to be installed in these sections The fan casing is made of aluzinc For easy inst...

Page 7: ...gh of the unit refer to the Technical data section Fasteners for unit mounting should be selected by the service technician 1 Mark the holes for mounting the fan 2 Drill the holes according to the mar...

Page 8: ...nnecting several fans simultaneously provided that their combined capacity and working current remain within the nominal parameters of the regulator External control units are purchased separately sho...

Page 9: ...tion at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS MAKE SURE THE UNIT IS DISCONN...

Page 10: ...Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual includi...

Page 11: ...TE The unit _____________________________________ is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Techni...

Page 12: ...V143 1EN 02...

Reviews: