All operations described in this manual must be performed by qualified personnel only, properly 
trained and qualified to install, make electrical connections and maintain ventilation units.
Do not attempt to install the product, connect it to the mains, or perform maintenance yourself.
This is unsafe and impossible without special knowledge.
Disconnect the power supply prior to any operations with the unit.
All user’s manual requirements as well as the provisions of all the applicable local and national 
construction, electrical, and technical norms and standards must be observed when installing 
and operating the unit.
Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and 
repair operations. 

Only  qualified electricians with a work permit for electrical units up to 1000 V are 

allowed for installation. The present user’s manual should be carefully read before 

beginning works.

Check the unit for any visible damage of the impeller, the casing, and the grille before starting 
installation. The casing internals must be free of any foreign objects that can damage the 
impeller blades. 
While mounting the unit, avoid compression of the casing! Deformation of the casing may result 
in motor jam and excessive noise.
Misuse of the unit and any unauthorised modifications are not allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous 
materials.
Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, 
insecticides, etc.
Do not close or block the intake or extract vents in order to ensure the efficient air flow.
Do not sit on the unit and do not put objects on it.
The information in this user’s manual was correct at the time of the document’s preparation. 
The Company reserves the right to modify the technical characteristics, design, or configuration 
of its products at any time in order to incorporate the latest technological developments.
Never touch the unit with wet or damp hands.
Never touch the unit when barefoot.
BEFORE INSTALLING ADDITIONAL EXTERNAL DEVICES, READ THE RELEVANT USER MANUALS.

Summary of Contents for OV1 200

Page 1: ...USER S MANUAL Electric axial fans OV1 OVK1 VKOM...

Page 2: ...has a contact separation in all poles that allows for full disconnection under overvoltage category III conditions CAUTION In order to avoid a safety hazard due to inadvertent resetting of the thermal...

Page 3: ...eck the unit for any visible damage of the impeller the casing and the grille before starting installation The casing internals must be free of any foreign objects that can damage the impeller blades...

Page 4: ...ances fibrous materials coarsedust sootandoilparticlesorenvironmentsfavorablefortheformationofhazardoussubstances toxicsubstances dust pathogenic germs The unit is rated as a Class I electrical applia...

Page 5: ...2 5 8 5 1 2 OV1 315 12 5 16 3 8 16 15 16 14 15 16 6 11 16 OV1 Model Measurements in D D1 D2 d L OVK1 200 8 3 16 10 5 8 11 13 16 1 4 4 3 4 OVK1 250 10 5 16 13 14 3 16 1 4 5 1 2 OVK1 315 12 5 16 15 3 88...

Page 6: ...d with bolts 4 The motor and impeller 5 are mounted on a bracket inside the casing The fans are equipped with a terminal box with a cable for remote connection OV1 OVK1 3 4 1 2 5 3 4 1 2 5 VKOM fan Th...

Page 7: ...nance technical service and replacement operations When the service conditions may lead to water ingress the fans must be equipped with adequate protection For example the fans may be installed under...

Page 8: ...8 OV1 OVK1 VKOM www vents us com OV1 and OVK1 fan installation...

Page 9: ...ed with clamps The power is supplied via terminal box on the fan casing The VKOM z delivery set includes mounting brackets for attaching the unit to the mounting surface Depending on a delivery set tw...

Page 10: ...short circuit The position of the external automatic circuit breaker must ensure free access for quick power off of the unit The trip current of the automatic circuit breaker must exceed the maximum c...

Page 11: ...11 www vents us com OV1 OVK1 fan connection VKOM fan connection...

Page 12: ...ater penetration onto the electric motor Wipe the cleaned surfaces dry To carry out technical maintenance of the VKOM fans remove the fans from the duct by undoing the retaining bolts on the units or...

Page 13: ...open If the malfunction is too complex to be eliminated on the spot contact the fan Seller STORAGE AND TRANSPORTATION REGULATIONS Store the unit in the manufacturer s original packaging box in a dry...

Page 14: ...any implied warranty is limited to the time period specified for the express warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply t...

Page 15: ...e _____________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician...

Page 16: ...VUSA03EN 13...

Reviews: