VENTRY Electric Fan O
wner’s Manual Insert continued
Manufactured by Ventry Solutions, Inc. (888) 257-8967
2010-08-05
Specifications
Motor:
1.5 HP / 1.1 kW
Volume:
12,080 cfm, 9.3 pounds thrust
Wattage:
2400 watts
Amps:
20 Amp or less, even at start up (no initial spike)
Input:
Single phase, 99-126V (voltage range: 110V +/- 10%), 50/60 Hz +/- 5%
(plugs in to normal household current)
Output to motor:
Three-phase (the drive converts single phase to three phase)
Controller:
Variable frequency drive - allows variable speed from 0 to 3600 RPM
GFCI:
Not for use on GFCI-protected circuits
Listed:
All electrical components are UL and CSA listed
Nema Plug:
Locking plug L5-20 (standard) or non-locking 5-20; others upon request
Dimensions:
23.75h x 23.25w x 21.25d inches (with legs retracted for storage).
Weight:
69 pounds (base model without options)
Optional:
Wheels & Folding Tow Handle (does not retrofit) and low-pressure filtered
water Misting Ring Kit for cooling/rehab (does retrofit)
Plugs and Cords
Any extension cord you choose to use with this electric fan must have an ampacity of
20 amps or greater. You can run 12 gauge up to 250 feet long. Anything longer than
250 feet must be 10 gauge.
Power Supply
While programmed not to exceed 20 amps, even at start-up, the 1.5 hp VENTRY
Electric Fan
requires a full 20 amps of power for maximum air volume. The fan’s speed
may be reduced using the Variable Speed dial to allow for a lesser power supply, but air
volume will also decrease. Many factors affect your power supply, including other
equipment drawing power from the same circuit and the gauge and length of cord into
which the fan may be plugged.
Flashing Red Line Displayed
During operation, if a red line flashes on the digital display, it is an indication that one or
more power-related limits have been exceeded. The blinking line will appear
immediately when the power available is inadequate for the fan’s current setting. Turn
down the Variable Speed dial if this occurs. As a safety feature, if speed is not reduced
promptly, the fan will automatically shut off to prevent damage. Should this occur, check
your power supply, restart the fan, and adjust the variable speed.
The 1.5 hp Electric VENTRY Fans come
with a 20 Amp plug wired on. Locking
NEMA L5-20 (picture A) is recommended
and used by default if not specified. Non-
Locking NEMA plug 5-20 (picture B) is
also available.
A
B