background image

VENTRY Electric Fan O

wner’s Manual Insert continued 

Manufactured by Ventry Solutions, Inc. (888) 257-8967 

2010-08-05 

 

Specifications  

Motor: 

1.5 HP / 1.1 kW 

Volume: 

12,080 cfm, 9.3 pounds thrust 

Wattage: 

2400 watts 

Amps: 

20 Amp or less, even at start up (no initial spike) 

Input: 

Single phase, 99-126V (voltage range: 110V +/- 10%), 50/60 Hz +/- 5% 

(plugs in to normal household current) 

Output to motor: 

Three-phase (the drive converts single phase to three phase) 

Controller: 

Variable frequency drive - allows variable speed from 0 to 3600 RPM 

GFCI: 

Not for use on GFCI-protected circuits 

Listed: 

All electrical components are UL and CSA listed  

Nema Plug: 

Locking plug L5-20 (standard) or non-locking 5-20; others upon request 

Dimensions: 

23.75h x 23.25w x 21.25d inches (with legs retracted for storage). 

Weight: 

69 pounds (base model without options) 

Optional: 

Wheels & Folding Tow Handle (does not retrofit) and low-pressure filtered 

water Misting Ring Kit for cooling/rehab (does retrofit) 

Plugs and Cords 

Any extension cord you choose to use with this electric fan must have an ampacity of 
20 amps or greater. You can run 12 gauge up to 250 feet long. Anything longer than 
250 feet must be 10 gauge. 

Power Supply 

While programmed not to exceed 20 amps, even at start-up, the 1.5 hp VENTRY 
Electric Fan 

requires a full 20 amps of power for maximum air volume. The fan’s speed 

may be reduced using the Variable Speed dial to allow for a lesser power supply, but air 
volume will also decrease. Many factors affect your power supply, including other 
equipment drawing power from the same circuit and the gauge and length of cord into 
which the fan may be plugged. 

Flashing Red Line Displayed 

During operation, if a red line flashes on the digital display, it is an indication that one or 
more power-related limits have been exceeded. The blinking line will appear 
immediately when the power available is inadequate for the fan’s current setting. Turn 
down the Variable Speed dial if this occurs. As a safety feature, if speed is not reduced 
promptly, the fan will automatically shut off to prevent damage. Should this occur, check 
your power supply, restart the fan, and adjust the variable speed. 

 

The 1.5 hp Electric VENTRY Fans come 
with a 20 Amp plug wired on. Locking 
NEMA L5-20 (picture A) is recommended 
and used by default if not specified. Non-
Locking NEMA plug 5-20 (picture B) is 
also available. 

 