SERVICE
Service - 61
Storage
Preparing the Power Unit for Storage
1. Clean the power unit.
2.
Attention
To maintain the finish of the power unit and attach-
ment, thoroughly wash the equipment to remove any
corrosive agents (e.g., salt). Failure to clean the equip-
ment may result in corrosion of (including but not lim-
ited to) steel, aluminum, and electrical components.
Inspect for loose or missing hardware, damaged
components, or signs of wear.
3. Inspect the ROPS structure and seat belt for
damage or signs of wear..
4. Inspect safety decals. Replace any safety decals
that are faded, illegible, or missing.
5. Inspect hydraulic hoses for leaks and/or wear.
Service as required.
6. Inspect hydraulic hoses, hydraulic fittings, and
fuel lines to ensure tight, leak free connections.
7. Ensure parking brake tension is properly adjusted.
8. Inspect electrical system and connections.
9. Test the operator safety interlock system.
10. Perform a TCM (tractor control module) check
to make sure the inputs and outputs are correct.
Refer to the troubleshooting section for input
and output information.
11. Inspect the PTO pulley and belt for damage or
excessive wear. Service as required.
12. Inspect the electric PTO clutch air gap. Set gap
to .020” (.5 mm).
13. Check the hydraulic oil level. Add fluid or service
as required.
14. Check the coolant level and make sure the
temperature protection range is at least -34° F
(-37° C). Add fluid or service as required.
15. Ensure the radiator screen, air cleaner, and
engine compartment are clean.
16. Check tires for proper inflation.
17. Grease and lubricate all points specified in
the maintenance section. Wipe off any excess
grease or oil.
After all the above steps have been performed,
complete the preparation for storage by performing
the steps for either long term storage (4 months or
longer) or short term storage (less than 4 months).
Long Term Storage (4 Months or Longer)
1. Change the engine oil to prevent damage that can
be caused by acidic build up in used motor oil.
2. Add a quality diesel fuel treatment to the fuel
tank. Follow the manufacturer’s recommended
mixing ratios.
3. Start the power unit’s engine and run for 10
minutes to allow the fuel treatment to travel all
through the fuel system.
4. Turn the key to the off position and remove.
5. Engage the parking brake.
6. Turn the fuel shut-off valve to the Off position.
7. Turn the battery disconnect to the Off position.
8. If the power unit is being stored in a cold climate
(below 35° F (2° C)), remove the battery from
the power unit and store in a warm location.
Check the battery charge level periodically and
charge the battery, if necessary.
Short Term Storage (Less than 4 Months)
1. Add a quality diesel fuel treatment to the fuel
tank. Follow the manufacturer’s recommended
mixing ratios.
2. Start the power unit’s engine and run for 10
minutes to allow the fuel stabilizer to travel all
through the fuel system.
3. Turn off the power unit engine and remove the key.
4. Engage the parking brake.
5. Turn the fuel shut-off valve to the Off position.
6. Turn the battery disconnect to the Off position.
7. Check the battery charge level periodically and
charge the battery, if necessary.
Removing the Power Unit from Storage
1. Inspect, clean, and prepare the power unit for
use. Perform all the steps in the daily inspection
prior to use.