Ventpro Silenta-S Series User Manual Download Page 3

EN

The 

fan 

with timer

 starts operation as control voltage is 

supplied to LT input terminal. As control voltage is off the fan 
continues operating within the time period set by the regulated 
timer from 2 to 30 minutes. 
Adjust the timer operating time by means of rotating the 
potentiometer T adjusting screw clockwise to increase the 
delay time or counter-clockwise to decrease it. 
The 

fan equipped with delay timer and humidity sensor

 

starts operation either as control voltage is supplied to LT input 
terminal or as indoor humidity level exceeds the pre-set value 
regulated between 60% and 90%. 
As control voltage is off or as indoor humidity level drops below 
the pre-set  level the fan continues operating within the time 
period set by the regulated timer from 2 to 30 minutes. 
Adjust the timer operating time by means of rotating the 
potentiometer T adjusting screw clockwise to increase or 
counter-clockwise to decrease the delay time and 
potentiometer H adjusting screw clockwise to increase or 
counter-clockwise to decrease the humidity threshold value. 

Warning! The timer circuit is under voltage. 

Adjusting and regulating operations are allowed only after 
power is off. 
While adjusting the screws avoid excessive efforts to the screw 
driver.  
The wiring diagram for connection of the light to the fan timer 
controlled by a common switch is shown at fig. 15 and 25 
(S - external swich). 
After light is off the fan continues operating within the time 
period set by the regulated timer from 2 to 30 minutes. 

Any electric connections, adjustment, servicing and repair 
works are allowed only after the unit is disconnected from 
power mains.
Mounting and maintenance are allowed for duly qualified 
electricians with valid electrical work permit after careful study 
of the present user's manual. 
The single-phase power grid must comply with the acting 
local electrical norms and standards. 
The fixed electrical wiring must be equipped with an 
automatic circuit breaker.
The fan must be connected to the power grid through the 
automatic circuit breaker QF integrated into the fixed 
wiring system. 
The gap between the breaker contacts on all poles must 
be not less than 3 mm. 
Before installation check the fan for any visible damages 
of impeller and casing. The casing internals must be free 
of any foreign objects which can damage the impeller blades.
Misuse of the device or any unauthorized modification is 
not allowed. 
The unit is not to be used by children and persons with 
reduced physical, mental or sensory capacities, without 
proper practical experience or expertise, unless they are 
controlled or instructed on the unit operation by the person(s) 
responsible for their safety.
 Do not leave the children unattended to avoid their playing 
with the device. 
Take steps to prevent ingress of smoke, carbon monoxide 
and other combustion products into the room through open 
chimney flues or other fire-protection devices. 
Sufficient air supply must be provided for proper combustion 
and exhaust of gases through the flue (chimney) of fuel 
burning equipment to prevent backdrafting. 

3

CAUTION

!

Summary of Contents for Silenta-S Series

Page 1: ...EN AXIAL FANS user s manual 2 model VentPro S Series ...

Page 2: ...0 to 90 TP model is fitted with a motion sensor only Silenta M series V model is fitted with a built in switch K model is fitted with a backdraft damper Due to the constant improvements the construction of some models may slightly differ from those described in this manual The fans are mounted to walls ceilings in ventilation shaft or round air duct horizontally or vertically by four screws and do...

Page 3: ...hin the time period set by the regulated timer from 2 to 30 minutes Any electric connections adjustment servicing and repair works are allowed only after the unit is disconnected from power mains Mounting and maintenance are allowed for duly qualified electricians with valid electrical work permit after careful study of the present user s manual The single phase power grid must comply with the act...

Page 4: ...materials and vapors i e spirits gasoline insecticides etc Do not close or block the intake and exhaust vents not to disturb the natural air passage Do not sit or put objects on the unit WARRANTY While purchasing the unit the customer accepts the following warranty terms Manufacturer hereby guarantees normal operation of the unit for 60 months from the date of resale subject to the compliance with...

Page 5: ...the unit replacement shall not be indemnified The manufacturing warranty does not cover any transportation and handling costs and the risks resulted from improper switching off and or mounting dismantling the unit The contractor in charge for mounting electric and adjustment operations shall be responsible for warranty of these works In any case the indemnity amount shall not exceed the actually p...

Page 6: ...6 1 ...

Page 7: ...L L N N QF 7 2 5 8 3 6 9 4 7 10 series S ...

Page 8: ...S1 S1 L L N N S1 S1 LT LT L L N N L L N N L L N N S1 S1 S1 S1 L L N N L L N N 2min 30min T 60 90 H 2min 30min T 60 90 H 11 13 15 8 12 14 16 series S SV series ST STH series SVT SVTH ...

Page 9: ...QF L L N N 31 33 35 9 32 34 36 ...

Page 10: ...10 ...

Page 11: ... наименование и штамп продавца Sold Title of sales organization shop stamp Verkauft Bezeichnung und Stempel des Verkäufers Vendu le nom et le tampon du vendeur Venduto Nome e timbro rivenditore Verkocht door naam van de verkoper stempel van de verkoper Vendido el nombre y la estampilla del vendedor Vandut denumirea si stampila vanzatorului Проданий найменування та штамп продавця Sprzedano nazwa i ...

Page 12: ...voor het gebruik Вентилятор признан годным к эксплуатации The fan device is ready for operation Der Lüfter ist als betriebsfähig anerkannt Le ventilateur est reconnu valable à l exploitation l ventilatore è adatto per l uso El ventilador es válido para la explotación Ventilatorul este apt pentru exploatare Вентилятор визнано придатним до експлуатації Wentylator uznany zosta za nadaj cy siê do eksp...

Reviews: