Ventpro Silenta-S Series User Manual Download Page 2

2

EN

Read and save these instructions before installing the unit. 
Compliance with the manual instructions provides reliable service of the unit during 
all the service life period. Keep this manual available throughout the entire 
operating period. You may need to re-read it for your information. 

This user's manual contains technical description and data 
sheet, 

operation

 manual, installation guidelines and warranty 

conditions for the axial fan Silenta-S series designed for exhaust 
ventilation of small and medium-sized premises heated during 
winter time. 

The fans are made of white plastic and the front panel is available 
in white and metallic colour. 

The fan modification may include a protecting insect screen. 

The delivery set comprises: 
1. Fan - 1 pce; 
2. Screws and dowels - 4 pcs; 
3. User's manual;
4. Packing. 

The fans are designed for connection to 100, 125 and 150 mm 
air ducts. 

The fans are equipped with low-voltage fans.

"L"

 model is fitted with a ball bearing motor. 

"T"

 model is fitted with a regulated timer adjustable between 

2 and 30 minutes.  

"

T

H"

 model is fitted with a humidity sensor with operating 

threshold from 60% to 90%. 

"

T

P"

 model is fitted with a motion sensor 

(only Silenta-M series).

 

"V"

 model is fitted with a built-in switch. 

"K"

 model is fitted with a backdraft damper. 

Due to the constant improvements the construction of 
some models may slightly differ from those described
in this manual.

The fans are mounted to walls, ceilings, in ventilation shaft 
or round air duct horizontally or vertically by four screws 
and dowels (fig. 1). 

Mounting sequence for Silenta-S is shown in fig. 2-10 and 
the wiring diagram is shown in fig. 11-16. 

The fans are powered by AC 220-240V, 50 Hz single phase 
current and designed for continuous operation always 
connected to the electric mains.
Air flow direction must match the direction of the arrow 
on the fan casing. 

The fans are designed for operation at the ambient 
temperature range from +0°С up to +45°С. 
Ingress protection rating IP 34. 

Store the fan in manufacturer’s packaging in a ventilated 
room at temperatures b5°C and +40°C and relative 
humidity not more than 80% at +25°C. 

The fan surfaces require regular cleaning from dust and 
dirt. See the cleaning procedure at fig. 31-36 for Silenta-S 
fan series 

.

Clean the fan surfaces with a soft cloth wetted a solution of 
water and mild detergent solution. 

Avoid liquid dripping on the motor while cleaning the fan.  
Wipe the surfaces dry after cleaning. 

Summary of Contents for Silenta-S Series

Page 1: ...EN AXIAL FANS user s manual 2 model VentPro S Series ...

Page 2: ...0 to 90 TP model is fitted with a motion sensor only Silenta M series V model is fitted with a built in switch K model is fitted with a backdraft damper Due to the constant improvements the construction of some models may slightly differ from those described in this manual The fans are mounted to walls ceilings in ventilation shaft or round air duct horizontally or vertically by four screws and do...

Page 3: ...hin the time period set by the regulated timer from 2 to 30 minutes Any electric connections adjustment servicing and repair works are allowed only after the unit is disconnected from power mains Mounting and maintenance are allowed for duly qualified electricians with valid electrical work permit after careful study of the present user s manual The single phase power grid must comply with the act...

Page 4: ...materials and vapors i e spirits gasoline insecticides etc Do not close or block the intake and exhaust vents not to disturb the natural air passage Do not sit or put objects on the unit WARRANTY While purchasing the unit the customer accepts the following warranty terms Manufacturer hereby guarantees normal operation of the unit for 60 months from the date of resale subject to the compliance with...

Page 5: ...the unit replacement shall not be indemnified The manufacturing warranty does not cover any transportation and handling costs and the risks resulted from improper switching off and or mounting dismantling the unit The contractor in charge for mounting electric and adjustment operations shall be responsible for warranty of these works In any case the indemnity amount shall not exceed the actually p...

Page 6: ...6 1 ...

Page 7: ...L L N N QF 7 2 5 8 3 6 9 4 7 10 series S ...

Page 8: ...S1 S1 L L N N S1 S1 LT LT L L N N L L N N L L N N S1 S1 S1 S1 L L N N L L N N 2min 30min T 60 90 H 2min 30min T 60 90 H 11 13 15 8 12 14 16 series S SV series ST STH series SVT SVTH ...

Page 9: ...QF L L N N 31 33 35 9 32 34 36 ...

Page 10: ...10 ...

Page 11: ... наименование и штамп продавца Sold Title of sales organization shop stamp Verkauft Bezeichnung und Stempel des Verkäufers Vendu le nom et le tampon du vendeur Venduto Nome e timbro rivenditore Verkocht door naam van de verkoper stempel van de verkoper Vendido el nombre y la estampilla del vendedor Vandut denumirea si stampila vanzatorului Проданий найменування та штамп продавця Sprzedano nazwa i ...

Page 12: ...voor het gebruik Вентилятор признан годным к эксплуатации The fan device is ready for operation Der Lüfter ist als betriebsfähig anerkannt Le ventilateur est reconnu valable à l exploitation l ventilatore è adatto per l uso El ventilador es válido para la explotación Ventilatorul este apt pentru exploatare Вентилятор визнано придатним до експлуатації Wentylator uznany zosta za nadaj cy siê do eksp...

Reviews: