background image

www.ventev.com/infra

[email protected]

800.851.4965

16.  Identify the radio at the node you are troubleshooting via the radio’s serial number. The serial number is 

located on the label on the bottom of the radio if it is not available. The radio will have to be removed from 

the enclosure to view.  If you don’t see the breadcrumb radio with that serial number on the network in the 

"BREADCRUMB  TABLE" tab, then the radio is not operational.

17. Verify that the circles under the flags column in the "BREADCRUMB TABLE" tab are green. A green circle 

means the radios are connected. A blue circle means the radios are not connected.  If the blue LED is 

nonoperational, then the antennas, rf jumpers, or Solexy RF couplers are not operational.

18. Link on the "TOPOLOGY VIEW" tab.
19. From the main menu, select VIEW  -> TOPOLOGY LAYOUT -> DEFAULT LAYOUT.
20. Click on the light blue and green links between the radios in the "TOPOLOGY VIEW" tab to verify all the 

antennas are connected. There will be data listed in all fields in the pop-up window (shown below). The 

antenna with no data listed is not operational.

Screen shot of Steps #19 and #20

21. Click on the radio with serial number under test in the "TOPOLOGY VIEW" tab.
22. Click on the "PEERS" tab.
23. Verify all the antennas have good cost values. The cost should be under 1000. If the cost is over 1000, 

then there is interference in the area where the enclosure system is deployed which is not allowing it 

to connect. The enclosure system will need to be relocated.

Troubleshooting Guide for the

ES1-IS-2450 NEMA 4X Enclosure System for Rajant

Reviews: