background image

Ventamatic, Ltd.     P.O. Box 728, Mineral Wells, TX 76068-0728     1-800-433-1626     Fax: 940.325.9311     www.BVC.com

7

SPECIALIZED FEATURES

Daisy-Chain Capability

The air purifier is designed for optimal versatility and convenience. 
You  can  interconnect  up  to  three  units  by  plugging  the  third 
into the auxiliary outlet of the second and the second into the 
auxiliary outlet of the first to create a maximum of 500, 1000, or 
1500 CFM using only 1 electrical supply outlet.

Stacking the Unit

To save floor space during storage, up to 3 units can be stacked 
vertically. Orient the unit so the handle of the lower unit fits into 
the base of the upper unit. You can also stack them horizontally 
for space saving storage, or operate a unit with its outlet facing 
upward.

WARNING: When stacking units, 
beware of tipping.

Do not stack more than 3 units on 
top of each other.

Falling equipment could cause 
bodily harm.

WARNING: Foam cap must be removed when unit is 
operating.

- 6 - 

                      Specialized Features                               

Daisy-chain capability 

Our designed the air scrubber for optimal versatility. You can 

interconnect up to three units to create a maximum of 500, 

1000, or 1500 CFM using the auxiliary outlet on the unit’s 

control panel.   

 

Stacking the unit 

The handle of one unit fits into bottom of another unit.   

You can also stack them horizontally for space saving storage,   

or operate a unit with its outlet facing upward.

 

 

 

              

 
 

 

 

WARNING 

When stacking units,beware of tipping. 

Do not stack more than 3 units on top 

of each other. 

Falling equipment could cause bodily 

harm. 

 

WARNING:  
Must be remove foam cap when unit running

 

WARNING

WARNING

3

Summary of Contents for QuFRESH AS1000WHT

Page 1: ...le injury or death Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury DANGER Warning indicates a potentially hazardous situation which if not avoided could result in death or serious injury WARNING Caution indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Used to indicate an el...

Page 2: ...iltration system The unit removes airborne particles like dust mold spores pollen pet dander and other particles as small as 0 3 microns The unit s maximum 500 CFM motor draws air into three types of filters a pre filter an activated carbon filter and a HEPA H 13 filter The first stage of filtration captures larger particles the second stage of filtration effectively captures airborne toxicants an...

Page 3: ...e the appliance as a toy 3 Do not operate any product with a damaged power cord or plug after the product malfunctions or if the product is dropped or damaged in any way Return the complete product to the place of purchase for inspection repair or replacement 4 Switch off and unplug from the power socket when not in use before assembling or before cleaning 5 Do not operate in standing water 6 Keep...

Page 4: ...UCT IDENTIFICATION LOGO Air outlet Power cord Air inlet first stage pre filter Removable foam cap WARNING Must be remove when unit running Latches total 4pcs Handle Front housing Back housing WARNING Must be removed when unit is running WARNING PRODUCT IDENTIFICATION Diag 1 Product Identification Diag 2 Intake and filters ...

Page 5: ...d plug it into a different outlet Then push the RESET button and check to see if it is operating if so continue use if not contact your local distributor 4 CONTROL PANEL VARIABLE SPEED It control fan motor speed and unit ON OFF Maximum seting to 500CFM AMPS TIME Press keys The PCB can switched display motor actual running current and total running time CHANGE HEPA FILTER The change light illuminat...

Page 6: ...ilter Maintenance The air scrubber utilizes a 3 stage filtration system designed with the most advanced HEPA filtration technology available Please replace HEPA filter when the change filter indicator light comes on Inspect pre filter before each use Look for accumulated dust and dirt that could restrict airflow through the filter into the unit If any is visible replace out the pre filter For envi...

Page 7: ...rage or operate a unit with its outlet facing upward WARNING When stacking units beware of tipping Do not stack more than 3 units on top of each other Falling equipment could cause bodily harm WARNING Foam cap must be removed when unit is operating 6 Specialized Features Daisy chain capability Our designed the air scrubber for optimal versatility You can interconnect up to three units to create a ...

Page 8: ...ction Air intake restricted Remove any obstructions to airflow intake Blower wheel not turning Obstructed blower Remove obstruction Loose blower wheel set screw Tighten set screw WARNING DO NOT attempt to rectify faults using unqualified personnel If the problem you are experiencing is not listed here call your local distributor WARNING SPECIFICATIONS Power Supply 115V 60Hz 210W 1 8A Process Air M...

Page 9: ...r the repair or replacement and return to you of any part or component not covered by this warranty including parts or components damaged by you The company reserves the right to demand and receive written evidence of the date of purchase before undertaking its obligations under this warranty The right to demand and receive written evidence of date of purchase extends to all licensed dealers of Ve...

Reviews: