background image

  

HANGING THE FAN 

 

 

Lift the fan a

ssembly onto the mounting bracket. Ensure that slot (A) of the hanger ball is fully 

aligned/engaged with the Tab (B) of the mounting bracket (C) to prevent the fan from rotating 

when in operation. Fig. 3) 

Secure the safety wire to  

the ceiling joist or other suit- 

able fixing point. 

 

 

 

 

 

 

Fig. 3 

 

  

ANGLED CEILING INSTALLATION 

 

 

This fan hanging system supports a maximum 15-degree angled installation. (Fig 4) 

Please note: the Tab (B) on the hanging bracket that sits in the groove (A) on the hanging ball 

should be positioned at the highest point to ensure correct operation. 

 

 

 

 

  

FINISHING THE INSTALLATION 

 

 

• 

Complete the electrical connection at the mounting bracket terminal block. 

• 

Fix the EARTH cable from motor to the mounting bracket. 

NOTE: DC 3 is a Class I electrical product. 

(Refer to Fig 6.). 

 

Fig 6

 

 

Highest Point 

Fig 4 

 

 

 

 

 

 

Summary of Contents for DC 3 Series

Page 1: ...WH LWC DC31203BL DC31203BL L DC31203BLWC DC31203BL LWC Thank you for purchasing this quality Ventair DC ceiling fan To ensure correct function and safety please read all instructions before using the product and keep all instructions for future reference MUST BE INSTALLED BY A LICENSED ELECTRICIAN CAUTION Read Instructions Carefully For Safe Installation and Fan Operation DIY With LED L model ...

Page 2: ...sons 8 WARNING Light and fan must be connected to the same phase Before servicing ensure both light and fan circuits are disconnected Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous s...

Page 3: ... Wood screws 3 5x 20mm 5 Receiver x 1 6 Balancing Kit x 1 7 Blade screws x 6 5 x 16mm 7 Blade screws x 6 5 x 16mm 8 Wood screws for mounting bracket x 2 6 x 50mm 8 Wood screws for mounting bracket x 2 6 x 50mm Wood screw for safety wire x 1 6 x 50mm Wood screw for safety wire x 1 6 x 50mm Please note Check for any damage to the fan before installation Damage marks or scratches are not covered by t...

Page 4: ...is threaded into the support structure QUICK CLICK BLADE INSTALLATION BLADE ATTACHMENT 1 Insert the blades x3 into the blade holding slots on the motor housing 2 Insert the 2 safety screws being careful not to over tighten 3 Move motor housing canopy downward until covering the motor housing 4 PLEASE NOTE The bracket fixing screws provided are for use with the wooden structures only These screws a...

Page 5: ... ANGLEDCEILINGINSTALLATION This fan hanging system supports a maximum 15 degree angled installation Fig 4 Please note the Tab B on the hanging bracket that sits in the groove A on the hanging ball should be positioned at the highest point to ensure correct operation FINISHING THE INSTALLATION Complete the electrical connection at the mounting bracket terminal block Fix the EARTH cable from motor t...

Page 6: ...cket making sure the AC input connecter on the receiver is aligned with the AC port on the receiver Refer Fig 7 1 on page 8 Fig 7 1 Fig 7 2 Slide the canopy upwards into position over the mounting bracket then turn counter clockwise to twist lock into position Ensure all 4 tabs on the mount bracket are located correctly into the slots on the canopy Canopy should be sitting approx 3mm off the ceili...

Page 7: ...G 90 2 738 6 69 5 98 2 79 8 381 5 E 988 F G 6C 9 90 2 738 6 69 5 98 2 79 8 381 5 E 988 F G 6C 9 2 F G 90 2 738 6 69 5 98 2 79 8 381 5 E A F G 6 0 97 79 9 9 3 C 98 2 79 8 381 5 6 0 9 31 0 12 2 875B 9952 5 8 68 5 2 1 5201 7 ...

Page 8: ...4 B N B0 5B 4H H0 100 5 C 8OO9 O0B9D M9 9 9 N 86B 4H H0 94 1 18 4 05 C 5 9 O0B9D P51 94 9 H45 699B 85 Q4R C 699B SD 1 T91 94 9 H45 699B 85 Q 5 C 699B D PQUM M85 05 O9 9 5 06 05 C V V D W 1 9 FE G 45B FE G X 9 45B 0 B H0 O 5 O8O 91 0 1 45 9 A9 995 KK N K N 3K P51 94 9 A 59 1 T91 94 9 A 59 45 FE G 45B FE G LM 0 4 B N B0 5B 4H H0 100 5 C 8OO9 O0B9D M9 9 9 N 86B 4H H0 94 1 18 4 05 C 5 9 O0B9D P51 94 9...

Page 9: ...E L9 B B C BH Q H J H 34 R 6 EL 4 GE 9 X L 4 A C F C A 1 X R C Z A BD QS 9 C L9 F 4 1 R 4 C ZD F D F F F E 1 X B F 4 4 E M F 4 F 1 Q8 0 99 G GI CB H C BH K BA DE L C E L H C F H X R A F F D E PF 2Q1 J4 F D F FF 2 99 88 381 R8 EC E L H LEJE L DE L9 B X J4 A F A P E Q F F PF 2Q C D F 4 D 4 F 4 4 F D 1 9 Handset ...

Page 10: ...3 secs to change between Forward and Reverse F and R will be visible on displayscreen Forward Downdraft for cooling summer mode Reverse Updraft for heat circulation winter mode 1 Increases fan speed until Max speed5 2 Presses and holds for minimum 3 secs to pair code with Tuya module APP if applicable Decreases fan speed until Min speed 1 1 Switches light 0 1 23 3242 5 6 7 6 8 6 0 4 7 29 74 6 00 7...

Page 11: ... a beep sound will be heard and within 20 seconds press and hold on the wall controller for 3 seconds The fan will emit another beep beep sound to indicate the pairing process is activated Using 1 wall controller to control 2 or more DC 3 Blade Ceiling fans Note ONLY 1 MASTER FAN CAN BE CONNECTED TO CONTROL BOX MAX 80 WATTS 1 Connect LIVE supply to L1 of the wall controller 2 Connect master fan to...

Page 12: ... will emit another beep beep sound to indicate the pairing process has been successful Repeat this process for each of the secondary fans IMPORTANT NOTES FOR MULTI FAN OPERATION All secondary fans should be within a 12m radius of the Master Wall controller to ensure reliable connectivity The Multi fan wiring format is different from the Single fan format This allows the isolation switch to cut pow...

Page 13: ...h to avoid scratching or marking the surface Please turn off electricity power when you do so Do not soak or immerse your ceiling fan in the water or other liquids It could damage the motor or the blades and create the possibility of an electrical shock Ensure that the fan does not come in contact with any organic solvents or cleaners To clean the fan blade wipe with only a damp clean cloth with N...

Page 14: ...elating to the installation contact your installer to rectify If you consider there is a manufacturer defect to the fan motor contact the warranty service line on 1300 665 926 or submit a warranty claim at www ventair com au warranty You will need to provide the following information The name and contact details of the licensed electrician installer The brand model number and serial number on moto...

Reviews: