HIGH AIRFLOW
3 IN 1 BATHROOM FAN, HEAT & LIGHT
IMPORTANT INSTALLATION INSTRUCTION AND WARRANTY INSTRUCTIONS
Thank you and congratulations on your purchase of the
Ventair 3 in 1 Bathroom Fan, Heat & Light. Please read these
instructions carefully before installing and using the product.
Keep the instructions handy for future reference.
Electrical wiring must only be done by a licensed electrician
and a “Certificate of Compliance” must be issued upon
completion of the installation.
LOCATION
The unit must be located and installed in accordance with
AS/NZS 3000 and local building codes and regulations
concerning the discharge of air have to be fulfilled.
The unit can be installed in any room that requires direct
radiant heating and circulated air flow such as bathrooms,
ensuites, laundries etc. The unit can be installed in flat ceilings
with a minimum height of 2 meters. At least 250mm height
clearance in the ceiling cavity is required to ensure sufficient
ventilation for moisture to disperse. The unit must also be
installed at least 400mm away from the walls.
Ensure adequate inlets exist through windows, vents or under
the door for air flow.
POWER
AC 220-240V, 50/60Hz electrical supply is required. The unit
can be connected to a lighting or power circuit if loading
permits. All electrical work must be carried out in accordance
with AS/NZS 3000 or latest edition thereof.
MOUNTING
1.The unit may be mounted either between
joists using the inbuilt clip fasteners or
against a joist using a screw through the
flange plate. Use this card in its open state
as a template. Place in the required
location and mark out the hole cutting
size. Hole size is 375mm x 375mm with a
160mm x 15mm bulge.
2.Before commencing cutting ensure that
the area behind the intended location is
clear of all cables, pipes and joists. Once
clear, cut out the section along the
previously marked lines.
3.Remove 4 heat lamps from the unit, then
remove the plug of the led downlight
inside the housing. Unfasten the fascia
retaining spring clips inside the housing,
and remove the fascia. Connect the
ducting (if required) to the outer grill of
the unit. Insert the unit into the square
hole being sure to pull the side springs
inward so that the body can pass through
the hole without damaging the plaster.
Ensure that the unit is held securely in
place by the clips. If required, additional
screws can be used to aid holding the unit
in the ceiling. Screw holes are provided in
the flange for this purpose.
4.Connect the led downlight plugs firstly.
Hold the fascia against the body of the
heater and the ceiling and attach the
securing spring clips to hold the fascia in
place.
5.Now screw in the four large heat lamps
into the lamp holder through the holes
provided in the fascia. The globes should
be screwed up firmly to ensure a good
electrical contact but don’t over tighten.
1
5
3
2
4