background image

ELECTRICAL WIRING 

The bathroom heater unit must be wired in accordance with 

Australian Wiring Rules AS/NZS 3000. 

Note: This unit is fitted with a thermostat switch which will 

operate to automatically switch the fan on in the event that the 

internal temperature of the unit exceeds 60

.

CARE AND MAINTENANCE

1.During the installation of this bathroom heater, please make sure 

that the person in the bathtub or in the shower area cannot reach the 

electrical switches and other electrical controllers.

2.This bathroom heater mustn’t be installed below the electrical outlet. 

3.This bathroom heater mustn’t be installed nearby the curtains 

and other combustible materials. 

4.This bathroom heater must under no circumstances be covered 

with insulation material or similar material.

5.Joists, beams and rafters shall not be cut or notched to install this 

bathroom heater.

6.Lamps must be cool before cleaning. To clean bulbs and surrounds, 

wipe with a cloth dampened with detergent or liquid glass cleaner.

7.To prolong the life of yours 3-in-1 bathroom heater fan light, avoid 

using heat lamp alone for longer than 10 minutes. Using the fan 

function along with the heat lamp to allow cooling of your 3-in-1 

bathroom heater light. 

8.This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for 

their safety. Children should be supervised to ensure that they do not 

play with the appliance.

REPLACEMENT LAMPS

HEAT LAMPS: The heat lamps must only be replaced with 275 

watt (maximum) lamps.

CENTRE LAMP: 10 watt (maximum) led downlight,4000K,700LM,

size:108mmx68mm(Available from place of purchase of  

Ventair Pty Ltd.)

This unit must be installed by a qualified licensed electrician.

Every Ventair 3 in 1 is thoroughly inspected and tested before being released for sale. In 

addition to any warranties or conditions implied by applicable Statue or Regulation, 

Ventair Design warrants all of its bathroom heaters against defective workmanship and 

faulty materials for 3 years from the original date of purchase. Ventair Design undertakes, 

at its option, to repair or replace, free of charge, each product or part thereof subject to 

the below warranty conditions:

1

.

The fan or relevant part has not been modified, subjected to misuse, neglect, or been involved 

in an accident.

2

.

The repairs are not required as a result of normal wear and tear.

3

.

The product was installed by a licensed electrical contractor in accordance with this instruction 

manual.

4

.

No solid state speed control device has been used with the appliance.

5

.

A copy of the original receipt of purchase is presented.

6

.

Globes supplied are not covered by this warranty.

Ventair can not be held responsible for any repair other than those carried out by it or one 

of its Authorised Service Agents. Please keep this warranty card in a safe place. This card 

must be produced in the event of service being required. 

MODEL (SKU) NUMBER:
DATE OF PURCHASE:
RETAILER:
RECEIPT NUMBER:
INSTALLED BY:
LICENSE#:                                      PH:                 
DESCRIPTION OF FAULT:

BATHROOM HEATER WARRANTY CARD

TERMINAL BLOCK

220-240V    a.c     50/60Hz

LIGHT: 10W led downlight

HEATER: 4 x 275W

FAN: 40W

375x375mm

VHF4W

Motor Power

Industry Standard

Reviews: