background image

Page 1

L108 1213A

UL

C

US

R

Read and Save These Instructions 

All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS 

WALL MOUNT LINER INSERT

Read All Instructions Thoroughly Before Beginning Installation

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s) 

in  accordance  with  all  applicable  codes  and  standards,  including  fire-

rated construction. Switch power off at service panel and lock the service 

disconnecting means to prevent power from being switched on accidentally 

during installation.

B.  When cutting or drilling into wall or ceiling, do not damage electrical wiring 

and other hidden utilities.

C.  Ducted fans must always be vented to the outdoors.

D. Sufficient air is needed for proper combustion and exhausting of gases 

through  the  flue  (chimney)  of  fuel  burning  equipment  to  prevent  back 

drafting.  Follow  the  heating  equipment  manufacturer’s  guideline  and 

safety standards such as those published by the National Fire Protection 

Association (NFPA), and the American Society for Heating, Refrigeration 

and Air Conditioning Engineers (ASHRAE), and local code authorities.

E.  ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to 

a maximum of 15 CFM per 100 square feet of occupiable space, unless a 

back drafting test is performed or make-up air is provided. Consult a local 

HVAC engineer for make-up air evaluation.

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL 

DUCTWORK

Summary of Contents for VP526

Page 1: ...nto wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire ...

Page 2: ...00 B200 10 round or equivalent 79 sq in VP562 Optional Two Duals Two B200s 12 round or equivalent 113 sq in VP563 Optional Ducting Requirements NEVER reduce the duct size When combining ducts together the square inch area must reflect the total square inch area of the ducts being combined Do not use flexible or corrugated duct This type of duct will restrict airflow and reduce performance Only use...

Page 3: ...of the liner allowing room for the transition if applicable If back venting the elbow s should be installed so that the non crimped end s are on the inside the collar s of the exhaust outlet s If a transition is used install duct down to the location of the transition outlet plus 1 This will allow the transition to engage 1 inside of duct Consult the connection diagrams next page for further detai...

Page 4: ... for step 10 5 Remove the shipping tape that is securing the E Z Clean shield s inside the hood Remove the E Z Clean shield s by lightly pulling it toward the front of the hood Gently close the back draft damper s from the top side of the hood To remove the blower housing s unsnap the suitcase latches one on each side of the housing The housing s should be pulled forward and gently tipped to clear...

Page 5: ...sly removed from the packaging in Step 4 11 Install the trim piece for the back side of the liner provided in the liner trim kit by hooking one side under the bottom edges of the back countersunk washers Snap the trim piece over the top of the countersunk washers by applying pressure upward and toward the liner wall Repeat this process for the side trim pieces provided in the liner trim kit Note I...

Page 6: ... 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MODEL DIM VP513 VP514 VP515 6 Round 7 Round 8 Round 6 7 8 VP513 8 VP514 9 9 16 VP515 10 5 8 BACK SIDE VENT ELBOW MODEL ...

Reviews: