14
every 10-14 days
illustration 4:
Switch off appliance and pull out switching power supply. Pour out soiled water.
Brush off precipitated deposits in the lower housing and flush out. Flush disk stack with water. Fill
lower housing with water again. Refill with Venta hygiene agent. For dosing, see scale on back of
bottle.
All residues in the lower housing and on the disk stack (white, green-yellowish or brownish precipi-
tation) do NOT impair the function of the Venta Airwasher. As a result of the addition of the hygiene
agent, trouble-free hygienic operation is guaranteed.
Dosage for models
LW 15 = Dosage for LW 14, LW 25 = Dosage for LW 24, LW 45 = Dosage for LW 44
See back of the bottle.
every six months
We recommend a six-monthly general cleaning with the Venta Cleaner. According to the degree
of pollution of the air washer, odors can possibly arise during cleaning. Please provide for fresh air
ventilation in these cases. The Venta Cleaner was especially designed to be compatible with Venta
plastics, without attacking them. Please consider directions for use on bottle.
generaL cLeaning
illustration 5:
Switch off the appliance and pull out switching power supply. For the opening of
the upper housing, press on the locking latch (see arrows).
illustration 6:
It is absolutely necessary to consider the sequence during the opening of
the top cover: First pivot aside the two sides
1
+
2
(with light pressure) and after that pivot
out the two ribbed wings
3
+
4
.
illustration 7:
Remove mains cable connector from drive unit
1
. Lift out drive unit
2
. Remove
mains cable from holder
3
and pull out through opening in the upper housing
4
.
• Do not dismantle unit and switching power supply, do not immerse in water and do not bring
into contact with liquid!
• Clean drive unit, fan blade and gearing with dry cloth!
• Dismantled upper housing can be cleaned under flowing water.
• Dismantled upper housing must be completely dry before assembly!!!
illustration 8:
Place drive unit into the upper housing in correct alignment
1
. Pull mains cable
connector up from underneath through the opening of the upper housing
2
and plug into drive
unit until latched
3
. Clip mains cable into holder
4
.
illustration 9:
For the closing of the upper housing it is absolutely necessary to follow
the sequence: Place the external ends of the latches in the up position! First pivot up the two
ribbed wings
1
+
2
and press on the external ends of the latches (see rings). After that pivot
up the two side parts
3
+
4
and engage in latch.