3
The lead should be a minimum of 1mm sq in section connections should be made within a standard BS6220 5 amp
junction box.
Once the wiring to the lamp is complete the lamp bezel white or chrome can be fitted by locating the 3 lugs,
and twisting anti-clockwise.
Never
connect mains supply direct to the class III shower light. Power input
– 12 volts DC
B. WIRING.
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING
THE INSTALLATION / OR MAINTENANCE.
NOTE: The
Controller
MUST
be surface mounted to allow air to freely circulate around the unit. When installed in a loft void it
MUST NOT
be enclosed or covered with insulation.
1. Select and follow the appropriate wiring diagram (Fig. 3-4).
2. Check all connections have been made correctly and ensure all terminal connections and cable clamps are securely
fastened.
3. The cable entry must be made using the cable grommet.
4. Ensure the impeller rotates and is free from obstructions.
Fig. 3.
Lo-Carbon Vent-A-Light Standard Model.
Select the wiring configuration required for the Toilet or Bathroom
.
Fig. 4.
Lo-carbon Vent-A-Light T Timer Model.
Switch the selector jumper to the required mode.