The lead should be a minimum of 1mm sq in section connections should be made within a standard BS6220 5 amp 
junction box.

 

Once the wiring to the lamp is complete the lamp bezel white or chrome can be fitted by locating the 3 lugs, 

and twisting anti-clockwise.

 

Never 

connect mains supply direct to the class III shower light.    Power input 

– 12 volts DC 

B. WIRING. 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING 
THE INSTALLATION / OR MAINTENANCE. 

 

NOTE: The

 

Controller

 

MUST

 be surface mounted to allow air to freely circulate around the unit. When installed in a loft void it  

MUST NOT

 be enclosed or covered with insulation. 

 

1.  Select and follow the appropriate wiring diagram (Fig. 3-4). 
2.  Check all connections have been made correctly and ensure all terminal connections and cable clamps are securely 

fastened. 

3.  The cable entry must be made using the cable grommet. 
4.  Ensure the impeller rotates and is free from obstructions. 
 

Fig. 3. 
Lo-Carbon Vent-A-Light Standard Model.

 

Select the wiring configuration required for the Toilet or Bathroom

.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 4. 

Lo-carbon Vent-A-Light T Timer Model.  

Switch the selector jumper to the required mode. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Vent-A-Light Lo-Carbon Series

Page 1: ...ight Lo Carbon RANGE In Line Fan and light Kit Stock Ref N Lo Carbon Vent A Light Standard 441423A Lo Carbon Vent A Light Timer 441424A Installation and Wiring Instructions FAN UNITS 12V DC SELV CLASS III CONTROLLERS 220 240V 50Hz MAINS SUPPLY CLASS II WITH 12V DC SELV OUTPUT For both fan light assembly ...

Page 2: ... appliance K The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time L Where ducted Fans are used to handle moisture laden air a condensation trap should be fitted Horizontal ducts should be arranged to slope slightly downwards away from the Fan M This appliance is not intended for use by young children or infirm persons without supervision N...

Page 3: ...ANCE NOTE The Controller MUST be surface mounted to allow air to freely circulate around the unit When installed in a loft void it MUST NOT be enclosed or covered with insulation 1 Select and follow the appropriate wiring diagram Fig 3 4 2 Check all connections have been made correctly and ensure all terminal connections and cable clamps are securely fastened 3 The cable entry must be made using t...

Page 4: ...sex RH10 9YX UK NATIONAL CALL CENTRE Newton Road Crawley West Sussex RH10 9JA SALES ENQUIRIES Tel 0844 8560590 Fax 01293 565169 TECHNICAL SUPPORT Tel 0844 8560594 Fax 01293 539209 For details of the warranty and returns procedure please refer to www vent axia com or write to Vent Axia Ltd Fleming Way Crawley RH10 9YX 404177A 0213 The Guarantee Applicable only to products installed and used in the ...

Reviews: