Vent-Axia VASF100B Installation And Wiring Instructions Download Page 7

 

 

 

 

 

     Fig.5: 

VASF100HT

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

     

Fig.6:

 

VASF100BV, 

VASF100TV, VASF100HTV, VASF100TC, VASF100HTC

 

 
 
 
 
 
 
 
 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Timer 
Adjustment 
 
 

 

Speed selection (JP2)

The fan is factory set to low speed with jumper JP2 fitted. 
To activate the low speed setting remove jumper JP2. 
 

Timer Function (JP1) 

JP1 to activate the timer, remove the jumper. 
15min. timer = jumper in. 
No timer = jumper out. 

 
 
  

 

Humidity Adjustment 

To 

INCREASE SET POINT

, turn the adjuster 

clockwise

. This makes the controller LESS 

sensitive. 
 To 

REDUCE SET POINT

, turn the adjuster 

anti-clockwise

. This makes the controller 

MORE sensitive. 

Humidity 
Adjustment 
 
 
  

 

JP1 
 
 

 

JP2 
 
 

 

Speed 
Adjustment 
 
 
  

 

JP1 
 
 

 

JP2 
 
 

 

Ambient Response Humidity Function 

– HTV & HTC only 

The inbuilt humidity sensor automatically adjusts dependant on 
ambient conditions and does not need adjusting.  

 
Speed Selection 

Adjust the fan speed by turning the pot clockwise to increase, 
and anti-clockwise to decrease. For continuous running 
models, the trickle speed is approximately 50% of the chosen 
high speed. 
 

Comfort mode (JP2) 

– TV, HTV, TC & HTC only

 

JP2 should be connected to enable comfort mode. (default off). 
This feature delays the LS input boost operation for a 
maximum of 20 minutes to reduce noise and cold drafts while 
bathing. After the LS is disconnected, the fan will switch on for 
the same period the LS had been active (up to 20 minutes), 
plus the overrun time period if selected (0 or 15 minutes).

 

 

Timer Function (JP1) 

– TV, HTV, TC & HTC only 

JP1 to deactivate the timer, remove the jumper. 
15min. timer = jumper in. 
No timer = jumper out. 
 

 

 
 
  

 

Summary of Contents for VASF100B

Page 1: ...Wiring Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Silent Fan IPX5 220 240V 50Hz Stock Ref N 446658B VASF100B 446659B VASF100T 477436B VASF10...

Page 2: ...Vent Axia products E The Fan should only be used in conjunction with fixed wiring F When the Fan is used to remove air from a room containing a fuel burning appliance ensure that the air replacement...

Page 3: ...lation ensure impeller rotates freely and the shutters can open 6 Replace the grille and ensure the clips reactivate WALL MOUNTING 1 For wall mounting either cut a 115mm diameter hole for 100mm fans t...

Page 4: ...TALLATION OR MAINTENANCE Fixed Speed Range Fig1 2 3 4 5 VASF100B Basic Remote or light switch operation 2 Speed options selectable at install VASF100T Timer Overrun timer adjustable 5 30min 2 Speed op...

Page 5: ...the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits 2 Wipe the inlets and front face with a damp cloth until clean The fan has sealed for life bearings wh...

Page 6: ...line up the 4 clips on the rear of the cover and slide to the left until you hear a click Fig 4 VASF100B VASF100T Timer Adjustment JP5 Timer Adjustment To REDUCE the operating time use a small screwd...

Page 7: ...inbuilt humidity sensor automatically adjusts dependant on ambient conditions and does not need adjusting Speed Selection Adjust the fan speed by turning the pot clockwise to increase and anti clockwi...

Page 8: ...y material or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been instal...

Reviews: