WIRING

 

 

WARNING: THE FAN AND ANCILLARY CONTROL 
EQUIPMENT MUST BE ISOLATED FROM THE POWER 
SUPPLY DURING THE INSTALLATION / OR 
MAINTENANCE. 

 

IMPORTANT 

  The fan should only be used in conjunction with fixed wiring.  

  The cross - sectional area of supply cord used should be ranged from 0.75-1.5mm

2

  Cable entry can only be made from the rear of the fan.  

  The extraction fan is suitable for connection to 220-240V 50Hz supply.  

  The fan is a class ll double insulated product and 

MUST NOT 

be earthed. 

 

 

1.  Select and follow the appropriate wiring diagram. (Fig. 1 or 2) 
2.  Check all connections have been made correctly and ensure all terminal connections are securely 

fastened. 

3.  Ensure the impeller rotates and is free from obstructions. 

 
SETUP 

 

WARNING: THE FAN AND ANCILLARY CONTROL 
EQUIPMENT MUST BE ISOLATED FROM THE POWER 
SUPPLY DURING THE INSTALLATION / OR 
MAINTENANCE. 

 

Fixed Speed Range

 

– Fig1, 2, 3, 4 & 5 

 

VASF100B 

– Basic - Remote or light switch operation. 2 Speed options selectable at install. 

VASF100T 

– Timer* - Overrun timer adjustable 5-30min. 2 Speed options selectable at install. 

VASF100HT - Humidity Timer* - Humidity controlled with fixed 15min. timer overrun. 2 Speed option 
selectable at install. 

 

Variable Speed Range

 

– Fig1, 2, 3 & 6 

 

VASF100BV 

– Basic - Remote or light switch operation. Variable speed options selectable at install. 

VASF100TV 

– Timer* - Overrun timer adjustable 5-30min. Variable speed options selectable at install. 

VASF100HTV - Humidity Timer* - Humidity controlled with fixed 15min. timer overrun. Variable speed 
options selectable at install. 

 

Continuous Running Range

 

– Fig1, 2, 3 & 6 

 

VASF100TC 

– Timer* - Fixed 15min. overrun timer. Continuous running fan with variable speed options. 

VASF100HTC - Humidity Timer* - Humidity controlled with fixed 15min. timer overrun. Continuous running 
fan with variable speed options. 

 

*All timer versions require a third switch live wire for the timer to work. 

 
 

Summary of Contents for VASF100B

Page 1: ...Wiring Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Silent Fan IPX5 220 240V 50Hz Stock Ref N 446658B VASF100B 446659B VASF100T 477436B VASF10...

Page 2: ...Vent Axia products E The Fan should only be used in conjunction with fixed wiring F When the Fan is used to remove air from a room containing a fuel burning appliance ensure that the air replacement...

Page 3: ...lation ensure impeller rotates freely and the shutters can open 6 Replace the grille and ensure the clips reactivate WALL MOUNTING 1 For wall mounting either cut a 115mm diameter hole for 100mm fans t...

Page 4: ...TALLATION OR MAINTENANCE Fixed Speed Range Fig1 2 3 4 5 VASF100B Basic Remote or light switch operation 2 Speed options selectable at install VASF100T Timer Overrun timer adjustable 5 30min 2 Speed op...

Page 5: ...the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits 2 Wipe the inlets and front face with a damp cloth until clean The fan has sealed for life bearings wh...

Page 6: ...line up the 4 clips on the rear of the cover and slide to the left until you hear a click Fig 4 VASF100B VASF100T Timer Adjustment JP5 Timer Adjustment To REDUCE the operating time use a small screwd...

Page 7: ...inbuilt humidity sensor automatically adjusts dependant on ambient conditions and does not need adjusting Speed Selection Adjust the fan speed by turning the pot clockwise to increase and anti clockwi...

Page 8: ...y material or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been instal...

Reviews: