Vent-Axia VA140/150KP Installation And Wiring Instructions Download Page 7

 

 
 

Humidity and Time Set-Point Adjustment.

 

 
The fan’s Humidity Set-Point is factory set to switch the fan on at approximately 72%RH. The sensitivity may be 
adjusted from 65%RH - 90%RH, by altering the adjuster on the Fan PCB. 
The overrun Time period is factory set to approximately 15 minutes. The overrun time period may be adjusted from 
5-30 minutes, by altering the adjuster on the Fan PCB. 

 

Before adjusting the Set-Point, switch off the Mains Supply. 

 

1.  Remove the Indoor Grille [A]. Loosen the screw (top middle) of the Grille, to release front grille gently lever the 

Grille downwards away from the Inner Cover [B]. 

2.  Remove Inner Cover [B]. Loosen the screw (bottom middle) and release the inner grille gently from the Base 

Housing [D]. 

3.  To LOWER the Set-Point/ operating time, turn the indicated adjuster ANTI-CLOCKWISE. This makes the fan 

more sensitive to RH%, i.e. the fan will come on at a lower RH% or will reduce the overrun time. 

4.  To RAISE the Set-Point/ operating time, turn the adjuster CLOCKWISE. This makes the fan less sensitive to 

RH%, i.e. the fan will come on at a higher RH% or will increase the overrun time. 

5.  Replace the Inner Cover and Indoor Grille.  
6.  Reconnect the mains supply. 
 
 
 
 
 
 
 

Shutter Operation 
 

The shutter mechanism in all VA140/ 150 range fans will open approximately 40 seconds after the fan is turned On. 
The shutter will close about a minute after the fan is switched Off. 
 
 
 
 
 
 
 

C. 

SERVICING AND MAINTENANCE. 

 

WARNING: 

THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED  

FROM THE POWER SUPPLY DURING MAINTENANCE.

 

 

 
1.  At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build 

up of dirt or other deposits.  

2.  Remove the Indoor Grille (See Section A : 2 for instructions) and wash in warm soapy water. 
3.  Wipe the shutter blades with a damp cloth until clean. 
4.  Replace the Grille. 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for VA140/150KP

Page 1: ...140120C VA140 150KT 140220C VA140 150KHP 140320C VA140 150KHT 140420C VA140 150 RANGE Axial Kitchen Fans Installation and wiring Instructions 220 240V 50Hz READ IN CONJUNCTION WITH ILLUSTRATIONS PLEAS...

Page 2: ...m C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E It is recommended tha...

Page 3: ...tly from the Base Housing D 6 Remove the Cable Grommet C pierce cut a hole in the Grommet to suit the cable size maintaining the integrity of the seal and replace the grommet in the Base Housing to su...

Page 4: ...sure all terminal connections and cable clamps are securely fastened 3 The cable entry must be made using the cable grommet 4 Ensure the impeller rotates and is free from obstructions Fig 3 VA140 150K...

Page 5: ...Indoor Grille A Loosen the screw top middle of the Grille to release front grille gently lever the Grille downwards away from the Inner Cover B 2 Remove Inner Cover B Loosen the screw bottom middle an...

Page 6: ...ver B 2 Remove Inner Cover B Loosen the screw bottom middle and release the inner grille gently from the Base Housing D 3 To LOWER the Set Point turn the adjuster ANTI CLOCKWISE This makes the fan mor...

Page 7: ...akes the fan more sensitive to RH i e the fan will come on at a lower RH or will reduce the overrun time 4 To RAISE the Set Point operating time turn the adjuster CLOCKWISE This makes the fan less sen...

Page 8: ...t will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connec...